Regency FP90 Indoor Fireplace User Manual


 
FPI FP90 Wood Fireplace22
INSTALLATION
INSTALLATION
FAN INSTALLATION
NOTE: If optional Ashtray is installed, it must be removed before installing the fan.
The receptacle Box must be wired for the fan cable to be plugged into.
1) Remove the thumb screw from the fan transfer tray.
2) Slide fan transfer tray fully out through the bottom louver opening.
3) Mount the fan bracket onto the fan transfer tray using the two locating pins.
4) Slide the Control Box onto the Control Box Mounting Bracket located on the front of the fan transfer tray and secure with
the #8 x 3/8” screw provided (refer to Diagram 1).
5) Install the wiring as shown on the wiring diagram. Use the strength relief for running the wires from the fan transfer tray to
the receptacle box or the ground screw (refer to Diagram 2).
6) Slide the fan transfer tray back into the unit and hook up wires to the Control Box and mount the thermo disc in place.
Diagram 1
R
R
910-516
910-903
NEUTRAL - FROM FAN
910-896
F
F
THERMODISC 910-142
60T12
F
F
910-811
M
M
FAN 910-175
AX-3088
HOT - TO VARIABLE SWITCH
VARIABLE SWITCH 910-330
M
F
M
F
GROUND
GROUND
POWER CORD 910-519
Diagram 2