Regency FP90 Indoor Fireplace User Manual


 
FPI FP90 Wood Fireplace 11
INSTALLATION
Ventilated Chase Pan
BEFORE YOU START
Check your inventory list to be sure you have all the necessary parts supplied in good usable
condition. Check for any concealed damage. Check the operation of the combustion air damper.
When the damper is in the fully closed position, the damper handle should be to the left. When
damper is in the fully open position, the damper handle must be in the right position.
INSTALLATION COMPONENTS DIAGRAM
Installation Components
Note: Insulation does not come in contact
with Chimney. Maintain a 2" (51mm)
clearance.
INSTALLATION
CHIMNEY SYSTEM
CONSIDERATIONS
Regency’s FP90 Fireplace is to be installed with
one of the following Chimney Systems only.
Chimney systems only 8" (203mm) diameter
are to be used.
In U.S.A.
Any of the following air-cooled chimney systems
may be used:
1) Majestic SK8
2) Security FTF8
3) Superior TF8
4) Simpson DuraVent Dura-Plus
Note: Fireplace Adaptor must be purchased
with Fireplace when using air cooled. When
using DuraPlus, purchase adapter with
Chimney System from Chimney Supplier.
The use of only one of these systems is permitted
when installing the replace. Do not alter or mix
parts from other systems as this may cause a
potential hazard and void Regency’s limited
warranty.
Chimney Height
The total height of your chimney system from the
top of the replace to the chimney cap must not
exceed 40'(12m), and must also meet minimum
system height requirements. Please refer to
the ue manufacturer's instructions for speci c
details. Refer to Minimum Recommended Flue
Height section.
Chase Enclosure
This unit requires the chase to be ventilated
with one 30 sq. inch vent. Refer to Installation
Measurements section.
A chase is a vertical box-like structure constructed
to surround the replace and chimney. A
ventilated chase cap is highly recommended.
Refer to ue manufacturer's instructions for
reduced ue heights above chase terminations.
As with all chimney installations, avoid overhead
obstructions such as trees, power lines, etc.
A chase should be constructed just like any
outside wall, insulated and vapor barriered.
Please check with local building authorities. In
a cold climate, we recommend the base of the
chase be insulated between the solid continuous
oor beneath the replace and the chase bottom.
If used, the value and amount of chase insulation
in a cold climate installation is optional and not
required for safety. Insulation is recommended
to avoid heat loss.
Inside Wall
Rain Cap
Storm Collar
Roof Flashing
Attic Radiation
Shield
Nailing Strip
Outside Fresh
Air Duct
Hearth
Extension
Hearth Safety
Strip
Outside Air
Inlet
Framing
Chase Vent Grill
Alternate Position
Chase Vent Grill