Quadra-Fire VOYAGEUR-MBK Indoor Fireplace User Manual


 
Page 32
7063-173D
November 22, 2011
R
VOYAGEUR Wood Insert
B. Clearances to Combustibles, United States and Canada (UL and ULC)
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having juris-
diction
Fire Risk.
Comply with all minimum clearances to
combustibles as specifi ed.
Failure to comply may cause house fi re.
WARNING
Hearth Extension
A
B
*C
**
D
F
E
Insert
SideWall
Maximum Mantel Depth - 12 inch (305mm)
Fascia or Trim
Mantel
Fuel Door
29 in. (736mm)
Minimum from Top
of Fuel Loading
Door Opening
Mantel
Figure 32.1 - Mantel Clearance
* Maximum 1-1/2 inch (389mm) Top Trim Depth
** Maximum 3-1/2 inch (89mm) Side Trim Depth
A B C D
Masonry, Heat Circulating &
Factory-Built Fireplace
20.5 in.
(521mm)
29 in.
(736mm)
22 in.
(559mm)
10.5 in.
(267mm)
USA CANADA
HEARTH EXTENSION
E F E F
16 in. 8 in. 18 in.
(457mm)
12-1/4 in.
(318mm)
EMBER PROTECTION Required on all installations for USA and Canada
NOTE: All measurements are from the fuel
loading door opening.
Required Protection
Suggested Protection
NOTE: Keep Ashlip
Clear of Ashes
Figure 32.2
NOTE: Hearth Rug may be used in Suggested Area