Quadra-Fire VOYAGEUR-MBK Indoor Fireplace User Manual


 
November 22, 2011
7063-173D
Page 15
VOYAGEUR Wood Insert
R
O. Blower Operating Instructions
1. Initial (cold) startup: Open both controls fully by rais-
ing the Burn Rate Air Control all the way up until it stops
and PUSH the Start-up Air Control back until it stops.
The blower tends to cool the appliance. Leave the blower
off until the burn is well established, i.e., 30 minutes.
2. High Burn Setting: Both controls are open. Burn Rate
Air Control is pulled up and the Start-up Air Control is
fully pushed in. Blower may remain on.
3. Medium-High Burn Setting*: Burn Rate Air Control
is closed then opened to 1 inch to fully open (pull up).
Blower may remain on.
4. Medium-Low Burn Setting*: Burn Rate Air Control
is closed then opened to 1/4 inch to 1/2 inch (pull up).
Leave the blower off until the burn is well established, i.e.,
30 minutes.
5. Low Burn Setting*: Burn Rate Air Control is closed
(down position).
Leave the blower off until the burn is
well established, i.e., 30 minutes.
*NOTE: For burn settings 3 to 5 the Start-up Air Control
needs to be pushed in (Open) then pulled forward to
activate the Automatic Combustion Control (ACC).
NOTE: For maximum effi ciency and lowest emissions,
when operating the blower in either the automatic or
manual setting for the low and medium low burn settings
leave the blower off until the burn is well established, i.e.,
30 minutes.
6. The blower is equipped with a rheostat (speed control).
The highest blower speed is obtained by turning the
rheostat on, then adjusting back towards “OFF” as far
as possible without turning the blower off. For a low
blower speed, turn the control knob clockwise as far as
possible
Blower Controls Under Ash Lip
MANUAL: over-
rides the internal
snap disc
AUTO: Fan with turn ON/OFF
automatically and is controlled
by the internal Snap Disc
1. The blower will turn on/off automatically when set to
AUTO. Figure 15.1.
2. When set to MANUAL, the fan will turn on/off only when
you turn it on or off. This setting over-rides the internal
snap disc.
3. Swing the grille downward to expose the blower con-
trols. Adjust the speed of the fan by turning the HIGH/
LOW knob to the desired setting.
N. Blower Control Box & Snap Disc
Operating Instructions
Figure 15.1
NOTICE!
Do NOT operate a circulating fan within close proxim-
ity, approximately 4 ft (1.2m), of appliance
• Can reverse air fl ow, blowing hot air into appliance
cavity.
• Can damage appliance blower due to overheating.