Quadra-Fire VOYAGEUR-MBK Indoor Fireplace User Manual


 
November 22, 2011
7063-173D
Page 29
VOYAGEUR Wood Insert
R
10 ft. (305cm) or more
3 ft. (91cm) Minimum
Less than 10 ft. (305cm)
2 ft. (61cm) Minimum
3 ft. (91cm) Minimum
Wall or Parapet
Flat Roof
3 ft. (91cm)
Minimum
Less than 10 ft. (305cm)
2 ft. (61cm)
3 ft. (91cm)
Minimum
10 ft. (305cm) To Nearest Roofline
2 ft. (61cm)
Pitched Roof
These are safety requirements and are not meant to assure proper fl ue draft.
Figure 29.1
F. 2-10-3 Rule
Figure 29.2
This appliance is made with a 6 inch (152mm) diameter chimney connector as the fl ue collar on the unit.
Changing the diameter of the chimney can affect draft and cause poor performance.
It is not recommended to use offsets and elbows at altitudes above 4000 feet above sea level and or when
there are other factors that affect fl ue draft.