Quadra-Fire VOYAGEUR-MBK Indoor Fireplace User Manual


 
Page 10
7063-173D
November 22, 2011
R
VOYAGEUR Wood Insert
H. Air Controls
1. Start-Up Air Control
The function of the Start-Up Air Control is to activate the Auto-
matic Combustion Control system (ACC).
Push the Start-Up Air Control all the way back until it stops
and then pull forward to the front of the appliance until it
stops. Figure 10.1.
The air channel opens and allows air to enter the front of the
appliance for approximately 20-25 minutes.
The air channel gradually shuts down until it is completely
closed at the end of the 20-25 minutes.
The fi re is now controlled by the air supplied by the Burn
Rate Air Control. Figure 10.1.
This function should be performed each time you reload the
appliance.
2. Manual Timer Over-Ride
If you need to shut the ACC system off before it shuts itself off
after 25 minutes (i.e. overfi re situation), lift up on the Start-up
Air Control and pull away from the appliance. Figure 10.2.
Figure 10.1 Start-up and Burn Rate Air Controls
Figure 10.2 Manual Timer Over-Ride
3. Burn Rate Air Control
The air supply enters at the upper front of the fi rebox,
near the top of the glass door.
This preheated air supplies the necessary fresh oxy-
gen to mix with the unburned gases, helping to create
the second, third and fourth combustion process.
This air is regulated by the Burn Rate Air Control.
There are four settings High, Medium-High, Medium-
Low and Low.
When the control is raised all the way up it is on the
High setting and when pushed all the down it is on the
Low setting. Figure 11.1.
G. Automatic Combustion Control (ACC)
Typically, when you build a fi re, you open the air controls fully and
monitor the fi re to prevent it from going into an overfi re situation
and/or burning your wood up too quickly before you shut down
the air controls to the desired burn rate.
When using the Automatic Combustion Control (ACC) system,
you do not have to continually monitor the fi re. Once you set the
ACC system it will control the fi re for you. Follow the instructions
below to learn how to operate your stove with ease.
WARNING
Risk of Fire or Chimney Fire.
Avoid Overfi re
DO NOT over-ride the Automatic Combustion
Control when the burn rate is set to HIGH
Burn Rate Control
ACC Start-up
Air Control
HIGH
LOW
To activate: Push back until it stops
and then pull forward until it stops
Lift Up on Control and Pull
Away from Appliance