November 22, 2011
7063-173D
Page 11
VOYAGEUR Wood Insert
R
I. Burn Rates and Operating Effi ciency
For maximum operating effi ciency
1. Burn dry, well-seasoned wood.
2. Follow these burn rate instructions below and refer to
Figure 11.1.
*NOTE:
These are guidelines. Actual settings may vary with
type of wood, chimney draft, altitude and other variables.
Burn Rates
1. Starting a Fire and Reloading
• Open both controls fully by raising the Burn Rate Air Con-
trol all the way up until it stops and push the Start-up Air
Control back until it stops.
•
The blower tends to cool the appliance. Leave the blower
off until the burn is well established, i.e., 30 minutes.
• After loading the appliance with wood and starting the
fi re, set both controls to the desired setting by following
the burn rate instructions below.
2. High Burn Rate - Maximum Heat*
•
Raise the Burn Rate Air Control all the way up until it stops
(top marker) to a fully open position.
•
Push the Start-Up Air Control all the way back until it stops
and leave it there.
•
This setting over-rides the timer system (ACC) so you
must monitor the fi re closely while in this setting.
3.
Medium-High Burn Rate - 15,000 to 30,000 BTU/hr*
• Raise the Burn Rate Air Control all the way up until it
stops (top marker) to a fully open position.
• Push the Start-Up Air Control all the way back until it
stops and then pull forward until it stops.
• This activates the timer system (ACC).
4.
Medium-Low Burn Rate - 10,000 to 15,000 BTU/hr*
• Raise the Burn Rate Air Control up to the bottom of the
middle marker and stop.
• Push the Start-Up Air Control until it stops.
• This activates the timer system (ACC).
5. Low Burn Rate - Below 10,000 BTU/hr*
• Leave the Burn Rate Air Control at the bottom marker.
• Push the Start-Up Air Control all the way back until it
stops and then pull forward until it stops.
• This activates the timer system (ACC).
Figure 11.1 Activating Timer
NOTE: If control is pushed all the way in it over-rides the
timer (ACC).
HIGH
LOW
To Activate Timer: Push back
until it stops then pull forward until
it stops.
Burn Rate
Air Control
Start-Up
Air Control