4.8 PAN/TILT VOLTAGE SETTINGS
Refer to Table A for information regarding pan/tilt voltages.
4.9 RESET
If you experience control difficulties with your system, programming preset 94 will
reset the system. The receiver will go through a power-up routine and restart opera-
tion. Any presets programmed into memory will be retained. Refer to your controller
documentation for programming presets. The preset will work only when your sys-
tem is configured for Extended (32-bit) Coaxitron mode.
4.10 LRD41 ADDRESS SELECTION SWITCH SETTINGS
NOTE:
The LRD address selec-
tion switch is located on the left side
panel of the unit when looking at
the unit from the 37-pin connection
end. The ten position dip-switch, of
which only the first 5 positions are
used for P-type protocol, gives a
total of 32 addresses (see Table C
for D-Type protocol where the first
8 switch positions are used for ad-
dressing, giving a total of 255 ad-
dresses).
0 1 1 1 0 0 0 0 0 0
Address 15
** BAUD RATE
ON = 1
OFF = 0
Table B. Address Switch Settings for SW *P-Type Control
(For D-type control systems, refer to Table C)
Address SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8
1 OFF OFF OFF OFF OFF
2 ON OFF OFF OFF OFF
3 OFF ON OFF OFF OFF
4 ON ON OFF OFF OFF
5 OFF OFF ON OFF OFF
6 ON OFF ON OFF OFF
7 OFF ON ON OFF OFF
8 ON ON ON OFF OFF
9 OFF OFF OFF ON OFF
10 ON OFF OFF ON OFF
11 OFF ON OFF ON OFF
12 ON ON OFF ON OFF
13 OFF OFF ON ON OFF
14 ON OFF ON ON OFF
15 OFF ON ON ON OFF
16 ON ON ON ON OFF
17 OFF OFF OFF OFF ON
18 ON OFF OFF OFF ON
19 OFF ON OFF OFF ON
20 ON ON OFF OFF ON
21 OFF OFF ON OFF ON
22 ON OFF ON OFF ON
23 OFF ON ON OFF ON
24 ON ON ON OFF ON
25 OFF OFF OFF OFF ON
26 ON OFF OFF ON ON
27 OFF ON OFF ON ON
28 ON ON OFF ON ON
29 OFF OFF ON ON ON
30 ON OFF ON ON ON
31 OFF ON ON ON ON
32 ON ON ON ON ON
Baud Rate SW9 SW10
2400 OFF OFF
4800 ON OFF
9600 OFF ON
Sample Switch Setting and Address Decode
SW 6 thru 8 reserved
for future use; SW 9
and 10 set Baud Rate
(see below).
SW1 THROUGH SW5 ARE USED FOR ADDRESSING.
SW9 AND SW10 ARE USED FOR BAUD RATE.
** SEE TABLE BELOW FOR ALLOWABLE BAUD RATE
SETTINGS FOR 9750/60 MATRIX SYSTEM INTER-
FACES.
FOR AD EQUIPMENT, SEE TABLE C.
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW9 SW10
NOTE:
Switch settings
need to be made for
RS422 control only; when
using Coaxitron control,
switch settings are not ap-
plicable and can be ig-
nored.
*P-type control is RS485/422 that is
compatible with Pelco’s CM9750 con-
trol system.