Pelco IV SE Home Security System User Manual


 
C3434M-A (9/07) 57
ALARMS
The Spectra IV SE Horizon dome system has seven alarm inputs that can be programmed as high,
medium, or low priority. When an alarm is received, an input signal to the dome triggers the user-
defined action (go to preset, run pattern, etc.) programmed for the alarm.
There are three global alarm settings:
RESUME This mode lets the dome resume its previous activity (scan, pattern, or
previous position) after all alarms are cleared.
SEQUENCE This is the time the dome will perform an alarm activity when more than one
alarm of the same priority occurs at the same time.
RESET DELAY This is the amount of time the dome considers the alarm to be active after it
has physically cleared.
Use the following steps to program alarm settings.
1. Use the joystick to position the cursor beside ALARM SETTINGS. Press Iris Open.
2. Select the alarm number:
a. Use the joystick to position the cursor beside ALARM NUMBER.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view selections. Press Iris Open to enter selection.
EXIT
PELCO SPECTRA IV SE HORIZON
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
BACK
EXIT
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
DOME SETTINGS
BACK
EXIT
ALARM SETTINGS
ALARM NUMBER
ALARM PRIORITY
ALARM ACTION
ACTIVATE AUX
ALARM CONTACT
<EDIT SCHEDULE>
BACK
EXIT
RESUME
SEQUENCE (SECS)
RESET DELAY (SECS)
<ALARM SETTINGS>
ALARMS