Cornelius 10 Fan User Manual


 
44300381000
Trouble RemedyProbable Cause
COMMPRESSOR OPERATES
CONTINUOUSLS BUT DOES
NOT FORM SUFFICIENT ICE
BANK (CONTD)
E. Inoperative or disconnected
pulse-modulating expansion
valve (see applicable
REFRIGERATION FLOW
DIAGRAM).
E. Check that expansion valve is
operating by touch (should be
able to feel valve pulse).Check for
loose or disconnected wire to
solenoid coil. If necessary,
troubleshoot expansion valve with
a gage set to see if it is opening.
If expansion valve is not opening,
suction pressure will be in a
vacuum.
F. Inoperative control board. No
output from board to
solenoids.
F. Check LEDs on control board to
see if they are modulating. Check
for 24V output to pulse
modulating expansion valve (see
WIRING DIAGRAM). If control
board green LED is on and yellow
LED Is flashing; but no 24V
output, replace board.
NOTE: If overload protector cuts out compressor, condenser fan motor will continue to operate
otherwise; troubleshooting condenser fan motor problem is same as for ‘ ‘COMPRESSOR DOES NOT
OPERATE’’ paragraph plus the following:
CONDENSER FAN MOTOR
NOT OPERATING.
Standard Cooling Unit with
Condenser Coil and Fan
Assembly
A. Jumper cord loose or
disconnected from condenser
fan motor or terminals inside
control box. Broken wire in
cord.
A. Tighten connections or replace
cord.
B. Fan blade obstructed. B. Remove obstruction.
C. Inoperative condenser fan
motor.
C. Replace condenser fan motor.
Remote Condenser Coil and Fan
assembly.
A. Blown power circuit fuse. A. Replace power circuit fuse.
B. Fan blade obstructed. B. Remove obstruction.
C. Inoperative condenser fan
motor.
C. Replace condenser fan motor.
D. Cooling unit contactor
inoperable.
D. Replace Cooling Unit contactor.
AGITATOR MOTOR NOT
OPERATING.
A. Agitator motor propeller
obstructed.
A. Remove obstruction.
B. Low voltage. B. Voltage must be at least 208 volts
at compressor terminals when
compressor is trying to start
C. Loose, disconnected, or
broken wiring.
C. Tighten connections or replace
broken wiring.
D. Inoperative agitator motor. D. Replace agitator motor.