Cornelius 10 Fan User Manual


 
300381000 18
COOLING UNIT CARBONATED WATER CIRCULATING PUMP MOTOR LUBRICATION
Carbonated water circulating pump motor bearings must be oiled periodically as instructed.
REMOTE CONDENSER COIL AND FAN ASSY (IF APPLICABLE)
MAINTENANCE
(see Figure 6)
CAUTION: Remote Condenser Coil and Fan Assembly connected to this Cooling Unit is
equipped with a condenser coil that must be cleaned every 30-days. Allowing condenser
coil to become clogged will cause refrigeration system to overheat which will automatically
shut refrigeration system down. After condenser coil has been cleaned, high-pressure cutout
switch reset button on top of switches electrical control box under Cooling Unit top cover will
have to be pressed to restart refrigeration system. OPERATING COOLING UNIT IN THIS MANNER
FOR PROLONGED PERIOD OF TIME COULD RESULT IN COMPRESSOR FAILURE.
Area on top of and around Remote Condenser Coil and Fan Assembly must be kept free of obstructions at all
times. Condenser coil must be cleaned as instructed to maintain proper cooling of coil.
CLEANING CO
2
GAS CHECK VALVES
(see Figure 2 )
The CO
2
gas check valves must be inspected and serviced at least once a year under normal conditions and
after any CO
2
system servicing or disruption as instructed.