21. Repeat steps NO TAG and NO TAG preceding to purge sanitizing solution out of the remaining syrup
systems and
dispensing valves.
22. Remove potable water source from the syrup system.
STEP 5. PURGE WATER OUT OF SYRUP SYSTEMS (RESTORE OPERATION)
23. Syrup Tank Systems.
A. Noting syrup tanks CO
2
regulator pressure setting observed in step 4 preceding, readjust CO
2
regulator to the observed pressure setting,
B. Connect tanks containing syrup into syrup systems.
Bag-in-Box Syrup System.
C. Remove all bag valves from bag-in-box syrup containers outlet tubes connectors.
D. Connect bag-in-box syrup containers into the syrup systems.
24. Place waste container under dispensing valves. Dispense from all dispensing valves to permit syrup to
purge all potable water from the syrup systems and the dispensing valves. Continue to dispense from the
dispensing valves until only syrup is dispensed from the syrup systems and valves.
WARNING: To avoid possible personal injury or property damage, do not attempt to
remove the syrup tank cover until CO
2
pressure has been released from the tank.
25. Dispose of waste sanitizing solution in a sanitary sewer, not in a storm drain, then thoroughly rinse the
inside and the outside of the container that was used for sanitizing solution to remove all sanitizing solution
residue.
REPLENISHING CO
2
SUPPLY
WARNING: CO
2
displaces oxygen. Strict attention must be observed in the prevention of
CO
2
(carbon dioxide) gas leaks in the entire CO
2
and soft drink system. If a CO
2
gas leak is
suspected, particularly in a small area, immediately ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO
2
gas will experience
tremors which are followed rapidly by loss of consciousness and suffocation.
NOTE: When indicator on CO
2
cylinder primary CO
2
regulator assembly 1800-psi gage is in shaded
(‘‘change CO
2
cylinder’’) portion of dial, CO
2
cylinder is almost empty and should be changed.
1. Fully close (clockwise) CO
2
cylinder valve.
2. Slowly loosen primary CO
2
regulator assembly coupling nut allowing CO
2
pressure to escape, then remove
regulator assembly from empty CO
2
cylinder.
3. Unfasten safety chain and remove empty CO
2
cylinder.
WARNING: To avoid personal injury and/or property damage, always secure CO
2
cylinder in
upright position with safety chain to prevent it from falling over. Should valve become
accidentally damaged or broken off, CO
2
cylinder can cause serious personal injury.
4. Position CO
2
cylinder and secure with safety chain.
5. Make sure gasket is in place inside primary CO
2
regulator coupling nut, then install regulator on CO
2
cylinder.