Cornelius 10 Fan User Manual


 
41 300381000
Trouble RemedyProbable Cause
ONLY CARBONATED WATER
DISPENSED (CONTD)
E. Dispensing valve syrup flow
regulator, soft drink tank quick
disconnect, or syrup lines
restricted.
E. Sanitize syrup system as
instructed.
ONLY SYRUP DISPENSED. A. Plain water inlet supply line
shutoff valve closed.
A. Open plain water inlet supply line
shutoff valve.
B. CARBONATOR MOTORS
power switch in ‘‘OFF’’
position.
B. Place switch in ‘‘ON’’ position.
C. Water filter clogged. C. Replace water filter.
D. Frozen Hydro BoostÒ Coil. D. Allow Hydro BoostÒ Coil to thaw,
then check for refrigeration
problem.
WARM PRODUCT BEING
DISPENSED.
A. Carbonated water circulating
pump CIRCULATING MOTOR
power switch in ‘‘OFF’’
position.
A. Place circulating pump
CIRCULATING MOTOR power
switch in ‘‘ON’’ position.
B. Inoperable carbonated water
circulating pump or motor.
B. Replace pump or motor.
Trouble Probable Cause Remedy
TROUBLESHOOTING CARBONATOR
WATER PUMP MOTOR WILL
NOT OPERATE.
A. Inoperative water pump motor. A. Replace water pump motor.
B. Dirty balance mechanism. B. Clean balance mechanism.
C. Loose connections and/or
open electrical circuit.
C. Tighten connections and/or repair
open circuit.
D. Overheated motor cut off by
thermal overload protector.
D. Check for proper line voltage.
Check for restricted pump
discharge.
E. Inoperative level control
switches.
E. Replace level control switches.
F. Binding or damaged balance
mechanism.
F. Repair or replace balance
mechanism.
G. Water pump binding (new or
replacement pumps only).
G. Remove water pump from motor,
rotate pump or motor shaft 180
degrees, then recouple pump to
motor.
H. Water pump damaged. H. Replace water pump as
instructed.
I. Safety thermostat inoperative. I. Replace safety thermostat.
WATER PUMP MOTOR WILL
NOT SHUT OFF.
A. Foreign object restricting tank
movement.
A. Remove foreign object.
B. Dirty balance mechanism. B. Clean balance mechanism.
C. Leak in carbonated water line. C. Tighten or replace line.
D. Inoperative level control
switches.
D. Replace level control switches.