Heatiator GC150 Indoor Fireplace User Manual


 
4-99 19 21322M
GC150 SERIES DIRECT VENT GAS APPLIANCE
VI. OPERATING INSTRUCTIONS
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor's
FOR YOUR SAFETY READ BEFORE LIGHTING
phone. Follow the supplier's instructions.
If you cannot reach your gas supplier, call the fire depart-
ment.
C. Use only your hand to push in or turn knob. Never use tools. If
the knob will not push in or turn by hand, don't try to repair it;
call a qualified service technician. Forced or attempted repair
may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
1. Turn off the wall switch or set the thermo-
stat to the lowest setting.
2. Remove control access panel.
3. Turn gas line to CLOSED position. Do not force.
4. Replace control access panel.
STANDING PILOT
1. Turn off all wall switches to the appliance.
Lower bottom access panel. Turn wall switch to
the “OFF” position or set thermostat to lowest
setting.
Turn gas line to CLOSED. Wait 5 minutes to
clear out any gas. Then smell for gas, including
near the floor. If you smell gas, STOP! Follow
“B” in the safety information above on this label.
If you don’t smell gas, go to the next step.
Turn gas line to OPEN.
Turn pilot knob clockwise to “OFF”. (Knob may
have to be depressed to pass “PILOT” position.)
Locate pilot assembly inside unit.
Locate red ignitor button.
Turn pilot knob to “PILOT” and push in.
9. Continue to hold in pilot knob and push the red
ignitor button 12-15 times until small blue pilot
flame appears.
10. Continue to hold in pilot knob for approximately
one minute. Pilot should remain lit. If pilot goes
out, wait 5 minutes and repeat Steps 4-9.
To light the main burner, release and turn knob
counterclockwise to “ON”. If the fireplace is con-
nected to a wall switch, turn it to “ON”. Do not
light by hand.
12. If the appliance will not operate, follow the
instructions “To Turn Off Gas To Appliance” and
call your service technician or gas supplier.
STOP! Read the safety information above on this label!
WARNING! If you do not follow these instructions exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
2
4
5
6
7
8
11
11
2
3
4
5
6
7
8
3