Heat & Glo LifeStyle XLR-PB-AU Indoor Fireplace User Manual


 
Heat & Glo • XLR-N-AU, XLR-PB-AU • 2198-906 Rev. M • 5/1256
IntelliFirePlusIgnitionSystem-(continued)
Symptom PossibleCause CorrectiveAction
4. Pilot lights but contin-
ues to spark, and main
burner will not ignite.
(If the pilot continues
to spark after the
pilot ame has been lit,
ame rectication has
not occurred.)
a. A shorted or loose connection in ame
sensing rod.
Verify all connections to wiring diagram in manual. Verify
connections underneath pilot assembly are tight. Verify con-
nections are not grounding out to metal chassis, pilot burn-
er, pilot enclosure or screen if present, or any other metal
object.
b. Poor ame rectication or contaminated
ame sensing rod.
With xed glass assembly in place, verify that ame is en-
gulng ame sensing rod on left side of pilot hood. Flame
sensing rod should glow shortly after ignition. Verify cor-
rect pilot orice is installed and gas inlet is set to pressure
specications. Polish ame sensing rod with ne steel wool
to remove any contaminants that may have accumulated on
ame sensing rod.
c. Module is not grounded. Verify module is securely grounded to metal chassis of ap-
pliance. Verify that wire harness is rmly connected to the
module.
d. Damaged pilot assembly or contami-
nated ame sensing rod.
Verify that ceramic insulator around the ame sensing rod
is not cracked, damaged, or loose. Verify connection from
ame sensing rod to white sensor wire. Polish ame sens-
ing rod with ne steel wool to remove any contaminants
that may have accumulated on ame sensing rod. Verify
continuity with a multimeter with ohms set at lowest range.
Replace pilot if any damage is detected.
e. Module. Turn ON/OFF rocker switch or wall switch to OFF position.
Remove ignitor wire “I” from module. Place ON/OFF rocker
switch or wall switch in ON position. If there is no spark at “I”
terminal module must be replaced. If there is a spark at “I”
terminal, module is ne.
5. Carbon Deposition a. Log Placement Verify placement and assure ame is not excessively
impinging on log.
b. Shutter Setting Check to assure correct shutter setting for your model and
gas type.
c. Gas Type Assure correct fuel matches unit gas model and compo-
nents.