Heat & Glo LifeStyle XLR-PB-AU Indoor Fireplace User Manual


 
Heat & Glo • XLR-N-AU, XLR-PB-AU • 2198-906 Rev. M • 5/1248
Note:The lower cover panel must be pushed all the way
down. The outer nishing anges should line up. The
replace opening must be between 15-3/4 in. and 16
in. (400 mm and 410 mm) for the decorative fronts to t
correctly. See Figure 13.4, Figure 13.5 and Figure 13.6.
SealingJoints
All joints between the factory-installed non-combustible
board and 3/8 in. (10 mm) building material (dry wall,
plywood, wood composites, etc.) can be taped and sealed
with combustible drywall tape.
FIREPLACE OPENING
15-3/4 in. TO 16 in.
(400 mm TO 410 mm)
Figure13.4RequiredFireplaceOpeningHeight
Figure13.5LowerCoverPanelPositionedIncorrectly.
Figure13.6LowerCoverPanelPositionedCorrectly
LOWERFINISHFLANGE
RIGHTSIDE
FINISH
FLANGE
BOTTOMCOVERPANEL
RIGHTSIDE
FINISH
FLANGE
LOWERFINISHFLANGE
BOTTOMCOVERPANEL