Heat & Glo LifeStyle XLR-PB-AU Indoor Fireplace User Manual


 
49Heat & Glo • XLR-N-AU, XLR-PB-AU • 2198-906 Rev. M • 5/12
B. MantelandWallProjections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specied. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Failure to comply could cause re.
Note:For non-combustible replace nish material (marble,
stone, etc) specications refer to Section 13.C.
Figure13.7 ClearancesToCombustibleMantelsOrOther
CombustiblesAboveAppliance
Mantels(Combustible/Non-Combustible)
Figure13.8Non-CombustibleMantelLegorWall
Projections
(Acceptableonbothsidesofopening)
UNLIMITED
TOP VIEW
7 in.
(180 mm)
3 in.
(80 mm)
MIN.
FRAMING
1-1/4 in. (30 mm)
3/8 in. (10 mm) BUILDING MATERIAL
1-1/2 in. (37 mm)
FrontSideFinishingDetail
Figure13.9FrontSideFinishingDetail
14 in.
(360 mm)
MIN.
11-3/4 in. (300 mm)
MAX.
3/8 in. (10 mm)
Thick Wall
Sheathing
MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING
Note:For non-combustible replace nish material (marble,
stone, etc) specications refer to Section 13.C.
MantelLeg(Combustible/Non-Combustible)