Heat & Glo LifeStyle ESC-42ST Indoor Fireplace User Manual


 
Heat & Glo • ESC-42ST • 2146-900 Rev. o • 5/12 45
B. Facing Material
Metal front faces may be covered with non-combustible
materials only.
• Facing and/or nishing materials must not interfere with
air ow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as speci ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
0 in.
0 in.
0 in.
NON-COMBUSTIBLE
BOARD
COMBUSTIBLE MATERIAL
61-5/8 in.
47-1/8 in.
Figure 13.6 Noncombustible Facing Diagram
C. Doors
Only doors certi ed for use with this appliance model may
be used. Contact your dealer for a list of doors that may
be used. Once you have determined what kind of door
and nishing material is going to be used on the replace,
you may use the table below which shows the door mod-
els and the nishing material thickness allowed.
FS-E42-XX
FSA-ESC42ST-XX
(REQUIRES ARCHKIT-ESC-42ST)
Figure 13.7 Approved Doors for ESC-42ST
Figure 13.5
3-1/2 IN.
NO COMBUSTIBLES
IN THIS AREA
1/2 IN. BUILDING MATERIAL
(MAY BE COMBUSTIBLE)
COMBUSTIBLE
FRAMING
4 IN.
FACTORY-
SUPPLIED 1/2 IN.
NON-
COMBUSTIBLE
BOARD
39 IN.
23 IN.
Note: Optional rescreen sits out 1-1/2 inches from the face
of the replace. When using thin nishing material, you may
want to use thicker non-combustible backer board to bring
the nishing material ush with the rescreen. This is not