Heat & Glo LifeStyle ESC-42ST Indoor Fireplace User Manual


 
Heat & Glo • ESC-42ST • 2146-900 Rev. o • 5/1244
A. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as speci ed. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materi-
als (i.e., steel studs, concrete board, etc.) Failure to comply
could cause re.
13
13
Finishing
Combustible Mantel Legs or Wall Projections
Non-Combustible Mantel Legs or Wall Projections
1 IN. MIN.
13 IN. MIN.
FROM OPENING
COMBUSTIBLE WALL OR
MANTEL LEG
FIREPLACE
OPENING
7 IN.
6 IN. MIN. FROM
OPENING
6 IN.
MAX.
COMBUSTIBLE
MATERIAL
Figure 13.3 Clearances to Combustible Mantel Legs or Wall
Projections.
1 IN. MIN.
13 IN. MIN.
4 IN. MAX.
FIREPLACE
OPENING
NON-COMBUSTIBLE WALL
NON-COMBUSTIBLE
MANTEL LEG
Figure 13.4 Clearances to Non-Combustible Mantel Legs or
Wall Projections.
Combustible Mantels
Non-combustible Mantels
Figure 13.1 Clearances to Mantels or Other Combustibles
Above Appliance
Figure 13.2 Clearances to Mantels or other Non-Combustibles
Above Appliance
10 IN.
MIN.
FIREPLACE
OPENING
12 IN.
MAX.
FIREPLACE
OPENING
10 IN.
MIN.
4 IN.
MAX.
12 IN.
MAX.
NON-COMBUSTIBLE
MATERIAL