Heat & Glo LifeStyle 6000GCF-IPILP Indoor Fireplace User Manual


 
Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. F • 6/0822
2. Match the amount of vertical in the system with the chart
to nd the appropriate position to set the Flue Restrictor
(see Figure 7.7).
1 2 3 4 5
SETTING
1 2 3 4 5
Figure 7.8
3. Center the Flue Restrictor on vent and secure in place
by using two self-tapping screws (see Figure 7.8).
Figure 7.7
E. Installing the Fiberglass Gasket
The berglass gasket supplied in the manual bag seals
between the rst 8 inch (203 mm) vent component and
the outer replace wrap. Using 2 self-tapping screws from
the manual bag secure the gasket to the outer wrap (see
Figure 7.9).
Figure 7.9 Fiberglass Gasket
FIRST VENT
COMPONENT
FIBERGLASS
GASKET
OUTERWRAP
- CHART -
Vertical
Top Vent
NG
Top Vent
LP
4’ 1-1 No Restrictor
8’ 2-2 1-2
15’ 3-3 3-2
20’ 3-4 3-3
25’ 3-4 3-3
30’ 4-4 3-4
35’ 4-4 3-4
40’ 5-4 4-4
45’ 5-4 4-4
50’ 5-4 4-4