Harman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner System Stove User Manual


 
6
INSTALLATION
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
Stove to Left Side Wall 6” (150mm) Stove to Corner Wall 6” (150mm)
Stove to Right Side Wall 6” (150mm) Stove to Ceiling 30” (760mm)
Stove to Rear Wall 6” (150mm) Stove to 10” Deep Mantel 30” (760mm)
Max. Alcove Depth 24” (610mm)
Several issues must be addressed when selecting a suitable location for your FireLuxe. The minimum
clearances to combustible construction are listed below. In addition, access to the gas supply and electrical
supply must be considered. The location of the stove will also affect the venting requirements and you
must be certain the location will allow compliance with the venting requirements shown on pages 8 – 13.
You must also insure that your installation provides adequate accessibility clearance for servicing and
proper operation.
When the appliance is installed directly on carpeting or tile or other combustible material other than wood
flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the
appliance.
Installation and repair should be done by a qualified service person. The appliance should be inspected
before use and at least annually by a professional service person. More frequent cleaning may be required
due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartments,
burners and circulating air passageways of the appliance be kept clean.
CEILING MANTEL
CORNER
WALLS
A = 6” (150mm)
B = 6” (150mm)
C = 6” (150mm)
D = 24” (610mm) Max. Alcove Depth
E = 6” (150mm)
F = 30” (760mm)
G = 30” (760mm)
H = 10” (250mm) Max.
A
B
C
E
E
D
F
H
G