FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
THIS APPLIANCE HAS TWO SEPARATE BURNER AND GAS CONTROL SYSTEMS. ONE SYS-
TEM IS FOR THE MAIN HEATING BURNER AND THE SECOND IS FOR THE TOP COOKING
BURNER.
A. BEFORE OPERATING EITHER BURNER SYSTEM, smell around the appliance area for gas. Be
sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light the appliance.
Do not touch any electric switch; do not use any telephone in your building.
Immediately call your gas supplier from a neighbor’s telephone. Follow the gas supplier’s instruc-
tions.
If you cannot reach your gas supplier, call the fire department.
B. Use only your hand to operate the gas controls. Never use tools. If a knob will not push in or turn by
hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a
fire or explosion.
C. Do not use this appliance if any part has been under water. Immediately call a qualified service techni-
cian to inspect the appliance and to replace any part of the control system which has been under water.
AUTOMATIC IGNITION
1. STOP! Read the safety information above on this page.
2. This appliance is equipped with an ignition device that automatically lights the pilot. When using the
remote handset, do not try to light the pilot by hand.
3. Push the OFF button on the remote handset to insure the appliance is off.
4. Wait five (5) minutes to clear out any gas. Then smell for gas including near the floor. If you smell
gas, STOP! Follow A in the safety information above. If you don’t smell gas, proceed to step 5.
5. Turn the MAN-knob to the ON, full counterclockwise position. Refer to Fig.1 on page 24.
6. Simultaneously press and hold the (star) and
S(up arrow) on the remote control unit (See Fig. 2)
until a short acoustic signal confirms the start sequence has begun; release buttons. Continuing signals
confirms the ignition sequence is in process. Once pilot ignition is confirmed, there is main gas flow.
WARNING: When pilot ignition is confirmed, valve motor turns automatically to maximum flame
height.
NOTE: If the pilot does not stay lit after several tries, turn the main valve knob to OFF, full
clockwise position. Proceed to step 8.
7. Set the thermostat to the desired setting or use the remote control to adjust flame. In standby mode:
press
S(up arrow) to increase the flame height, press T(down arrow) to decrease flame height or
set appliance at pilot flame. See page 26 for remote handset programming instructions.
8. If appliance will not operate, follow instructions “TO TURN OFF GAS TO MAIN BURNER” on the
next page and call your service technician or gas supplier.
LIGHTING INSTRUCTIONS - MAIN BURNER
LIGHTING AND OPERATION