LIGHTING AND OPERATION
REMOTE CONTROL HANDSET
OPERATION AND PROGRAMMING
Flame Height Adjustment
PILOT FLAME ADJUSTMENT
The pilot flow is factory set to maximum. The pilot
flame should envelope 3/8” to 1/2” of the thermo-
couple. See the illustration above.
The adjustment screw can be reached through the
MAN-knob. See top illustration above.
1. Turn the Man-knob to the ON position.
2. It is now possible to pierce through a film on
the cover with a screwdriver to reach the adjust-
ment screw beneath.
3. Turn the adjustment screw clockwise to de-
crease or counterclockwise to increase pilot
flame.
CORRECT PILOT FLAMES
PILOT FLAME
ADJUSTMENT
CORRECT MAIN BURNER FLAMES
THERMOCOUPLE FLAME
“MAN”