Harman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner System Stove User Manual


 
5
SPECIFICATIONS
MAIN BURNER Natural Gas Propane (LP)
Input Rating-Btu/hr 36000 36000
Min. Input-Btu/hr 23000 23000
Orifice-DMS #34 #50
COOKING BURNER
Input Rating-Btu/hr 12000 12000
Min. Input-Btu/hr 3500 3500
Orifice-DMS #52 #58
GAS SUPPLY
Manifold Pressure 4.5”w.c./1.3kPa 10.0”w.c./2.5kPa
Min. Supply Pressure 5.0”w.c./1.3kPa 11.0”w.c./2.8kPa
Max. Supply Pressure 10.0”w.c./1.8kPa 13.0”w.c./3.3kPa
Annual Fuel Utilization Efficiency (AFUE) 72.7% 74.9%
Steady State Efficiency 73.4% 75.6%
It is recommended that the pilot flame be turned off if the appliance will not be in use for an
extended period of time.
This appliance is equipped for use with the fuel type indicated on the rating plate. Fuel conversion kits that
include the necessary parts and instructions are available from your installer, dealer or Harman Stove Co.
This appliance has been certified by OMNI-Test Laboratories, Inc. to ANSI Z21.88-2005 • CSA 2.33-2005
Vented Gas Fireplace Heaters and CAN1-2.17-M91, Gas-Fired Appliances for Use At High Altitudes.
The FireLuxe is approved for installation at elevations up to 2000 feet in the U.S. and 1370 meters (4500
feet) in Canada without change. If your installation is at an elevation greater than these, consult with the
local authority having jurisdiction for gas product installations to determine their specific requirements for
high altitude installations.
28” (71cm)
23 1/4” (59cm)
30 1/2” (77.5cm)
20 1/2”” (52cm)