Home Automation INC. Omni IIe Indoor Furnishings User Manual


 
The following control actions are allowed on PESMs:
Turn Energy Saver On and Off
Turn Energy Saver On and Off for a specified time
Set heating setpoint
Set cooling setpoint
You can turn the energy saver on, off, use a timed on/off, and change the Heat and Cool temperatures from the console or by
telephone. Commands can also be programmed so that they occur by time schedule or by event, such as security mode change.
For example, the system can be set up to turn the energy saver(s) On and make the Heat setback temperature 65 degrees and the
Cool setback temperature 80 degrees when the alarm system is put in the Away mode. Another program can turn the energy
saver(s) off (to resume normal operation of the HVAC system) at 4:30 P.M. on weekdays to make the house comfortable before
arriving home. Different setback temperatures could be set for the Night mode.
To set up your thermostat for use with the energy saver, set it in the appropriate mode and set the temperature to your preference.
NOTE: Your heating and cooling system will always be off if you set your thermostat to Off mode. The PESM cannot turn it
back on. The PESM cannot make your system cool below the thermostat's cool setting, or heat above the thermostat's heat
setting.
Control actions for temperature sensors:
Set low setpoint
Set high setpoint
To enter the temperature menu, from the top-level display or from the main menu, press the 5 (TEMP) key on the console keypad.
You will be prompted with the first named temperature zone (i.e. Upstairs). The temperature zone can be specified by entering
the temperature zone number followed by the ' # ' key, or by pressing the arrow keys to scroll through the list of temperature
zones. Press the ' # ' key when the desired temperature zone is shown.
TEMPERATURE ZONE:
ENTER TEMPERATURE ZONE
After the ' # ' key is pressed, a menu appropriate for the type of temperature zone is shown.
For Programmable Energy Saver Modules:
Upstairs
0=OFF 1=ON 2=HEAT
Upstairs
3=COOL 4=TIME #=STAT
For temperature sensors:
Upstairs
2=LOW 3=HIGH #=STAT
To set a temperature setpoint, press 2 (HEAT) or 3 (COOL).
For Celsius temperatures, press the ' # ' key prior to entering the temperature to make the number negative. The Celsius
temperature may also be specified in 0.5 degree steps if three numeric digits are entered. The third digit adds a .5 to the first two
digits if it is any- thing other than zero. Enter a leading zero if necessary.
In additions to setpoint changes, an energy saver may be turned On or Off. It may also be turned On or Off for a specific
duration.
To turn the energy saver Off, select 0 (OFF). To turn the energy saver On, select 1 (ON). To turn the energy saver On or Off for
a specific duration, select 9 (TIME) prior to selecting On or Off. Enter the time as described under Control - Unit Commands.
Downstairs
Page 32