Home Automation INC. Omni IIe Indoor Furnishings User Manual


 
ALL
0=OFF 1=ON 2=SCN 3=LINK
ALL
4=PHANTOM 5=CENLIT
All Lights On
At the ALL prompt, press the 1 (LIGHTS ON) key. The console will beep, and a command will be sent that turns on all specified
X-10 and ALC units and HLC Rooms. X-10 Appliance Modules do not respond when the All Lights On command is sent. All
House Codes (1-4), by factory default, respond to the All-On command.
NOTE: The All On function can be changed, if desired - See Set Up Misc, All On And All Off.
All Off
At the ALL prompt, press the 0 (OFF) key. The console will beep, and a command will be sent that turns off all specified X-10
and ALC units and HLC Rooms. All House Codes (1-4), by factory default, respond to the All-Off command.
NOTE: The All Off function can be changed, if desired - See Set Up Misc, All On And All Off.
Leviton Scene Control
Omni IIe supports Leviton Scene Control (a feature found in certain Leviton Switches). There are 64 Scenes that can be set and
executed. The Leviton Switches are divided into "lighting groups" of four units each. Each of these lighting groups can be set to
four different Scenes. Once the Scenes have been set up, a command can be sent to the units in that Scene to simultaneously
return to the preprogrammed lighting level.
Scene
There are 64 Leviton Scenes that can be set and executed. The X-10 units (unit numbers 1-64) are divided into "lighting groups"
of four units each. Each of these lighting groups can be set to four different Scenes. Scenes 1-4 apply to the first four unit
numbers (units 1-4), Scenes 5-8 to the next four unit numbers (units 5-8), and so on. Thus an easy correspondence is made
between Scene numbers and unit numbers.
SCENES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 X X X X
2 X X X X
3 X X X X
4 X X X X
5 X X X X
6 X X X X
7 X X X X
8 X X X X
9 X X X X
10 X X X X
11 X X X X
12 X X X X
13 X X X X
14 X X X X
15 X X X X
UNIT NUMBERS
16 X X X X
X - Corresponds to the unit numbers in a Scene.