Enviro 50-1040 Stove User Manual


 
32
Installation
Figure 35: Attaching removable ue.
Figure 36: Leveling leg.
SURROUND PANEL SEALED INSTALLATION FOR USA ONLY - INSERT:
Before starting this type of installation
refer to INSTALLATION - MASONRY FIREPLACE
INSTALLATION - INSERT for additional
information. For clearances refer to
SPECIFICATIONS - CLEARANCES TO COMBUSTIBLES
- 1200 INSERT and SPECIFICATIONS - CLEARANCES
TO COMBUSTIBLES - 1700 INSERT.
1. Before the face plate is installed
onto the unit, glue a 6” (150mm)
wide R20 berglass insulation strip
around the perimeter of the back of
the panels using RTV silicon or stove
gasket cement. When the face plate
is installed onto the unit the insulation
must overlaps the replace opening
to form a seal between the masonry
replace and the unit’s face plate. Let
the silicon or cement dry.
2. To make the installation of the surround
panel onto the unit easy have the unit
6” (150mm) out from the replace,
3. Push the insert into the replace,
allowing the insulation to form a seal
between the panels and the replace.
Tuck any exposed insulation behind the
face plate.
Figure 37: Installation with Surround Sealed.
Masonry Fireplace
Mantel
Damper Removed
or Fastened Open
Surround Panel
USA 16” (406 mm)
CND 18” (450 mm)
Insulation Around the
Back of the Face Plate
      
    
     
        
      
     
   
       
 