Enviro 50-1040 Stove User Manual


 
3
Safety Precautions
FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” WOOD
STOVE, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:
Please read this entire manual before you install and use your new woodstove. Failure to
follow instructions may result in property damage, bodily injury or even death. Be aware
that local Codes and Regulations may override some items in this manual. Check with your
local inspector.
● If this appliance is not properly installed, operated and maintained, a serious house re could result.
Do not use any makeshift materials during installation, maintenance, or replacement.
● Never place wood, paper, furniture, drapes or other combustible materials near the stove. Do not let
children or pets touch it when it is hot.
● Operate only with the door and ash pan tightly closed and burn wood directly on the stove hearth. Do
not operate if the door glass is broken or a gasket is missing or damaged. Do not alter the combustion
air control valves. Dangerous overring could occur which could ignite creosote in the chimney or
cause a house re.
● At least 12 square inches (77.4 cm
2
) of fresh outside air should be admitted into the room or directly
to the stove through a 4 inch (10.16 cm) diameter pipe. For the stove to operate combustion-air must
be supplied through either the bottom or the back of the pedestal.
● Do not burn coal or charcoal as there is danger of carbon monoxide being produced. Do not use
chemical uids to start or re-fresh the re. Do not burn garbage or ammable uids such as gasoline,
grease, naphtha or engine oil. Never let the stove become hot enough to get any part red or glowing
red.
● Burning wet, unseasoned wood could cause excessive creosote accumulation in the ue pipe. When
ignited, it could cause a chimney re that could result in a serious house re.
● Do not use grates, andirons or any other methods to support or raise the re up off the hearth of the
appliance.
● This appliance is tested to ULC-S627 Standard for Space Heaters for Use with Solid Fuel, ULC-S628
Standard for Fireplace Inserts, & UL 1482 Standard for Safety for Solid-Fuel Type Room Heaters.
● Both the 1200 & 1700 Fireplace Inserts are approved for installed into a zero-clearance replaces in the
U.S. In Canada refer to local building or re ofcials for restrictions and installation inspection
● In Canada the existing chimney must be lined to the termination for all masonry installs.
IMPORTANT: The following must be done
to ensure proper operation. Failure to do so
will cause extreme overheating and possible
personal injury or property damage:
• If an outside air supply has not been added to
this appliance, please ensure that the 4” inch
fresh air outlet on the back of the pedestal is
removed.
• Ensure that the ash dump grate and cover
plate are installed over the ash dump hole.