Enviro 50-1040 Stove User Manual


 
13
Specifications
CLEARANCES TO COMBUSTIBLES - 1200 INSERT:
A Minimum clearance to an unshielded side wall
10” (254 mm)
B Minimum clearance to an unshielded 8” (203 mm) mantle
21” (533 mm)
C Minimum top facing (protruding ” [19 mm]) clearance
17” (445 mm)
D Minimum side facing (protruding ” [19 mm]) clearance
1” (25 mm)
E † From front of door opening to edge of oor protection
USA 16” (406 mm)
CND 18” (450 mm)
F † From side/back of unit to edge of oor protection
USA 6” (152 mm)
CND 8” (200 mm)
FLOOR PROTECTION:
If unit is raised 0” - 2” (0mm-51mm); 1” (25mm) non-combustible material with k value = 0.84 or equivalent.
If unit is raised 2” - 8” (51mm-203mm); ” (13mm) non-combustible material with k value = 0.84 or equivalent.
If unit is raised greater than 8” (203 mm) or more; any non-combustible material can be used.
Masonry Zero Clearance
Minimum Depth 13” (343mm) 14” (279mm)
Minimum Width at back of replace 22” (568mm) 23” (584mm)
Minimum Width at front of replace 27” (686mm) 27” (692mm)
Minimum Width at front of replace to include shroud 33” (857mm) 34” (864mm)
Minimum Height 19” (489mm) 20” (508mm)
CLEARANCES TO COMBUSTIBLES - 1700 INSERT:
A Minimum clearance to an unshielded side wall
10” (254 mm)
B Minimum clearance to an unshielded 8” (203 mm) mantle
24” (610 mm)
C Minimum top facing (protruding ” [19 mm]) clearance
19” (495 mm)
D Minimum side facing (protruding ” [19 mm]) clearance
1” (25 mm)
E † From front of door opening to edge of oor protection
USA 16” (406 mm)
CND 18” (450 mm)
F † From side of unit to edge of oor protection
USA 6” (152 mm)
CND 8” (200 mm)
FLOOR PROTECTION:
If unit is raised 0” - 2” (0mm-51mm); 1” (25mm) non-combustible material with k value = 0.84 or equivalent.
If unit is raised 2” - 8” (51mm-203mm); ” (13mm) non-combustible material with k value = 0.84 or equivalent.
If unit is raised greater than 8” (203 mm) or more; any non-combustible material can be used.
Masonry Zero Clearance
Minimum Depth 18” (457mm) 18” (470mm)
Minimum Width at back of replace 22” (568mm) 23” (584mm)
Minimum Width at front of replace 27” (686mm) 27” (692mm)
Minimum Width at front of replace to include shroud 33” (857mm) 34” (864mm)
Minimum Height 19” (489mm) 20” (508mm)
 
Table 3: 1200 Insert Clearance to Combustibles.
 
Table 5: 1700 Insert Clearance to Combustibles.
Table 4: 1200 Insert Minimum Fireplace Size.