Enviro 50-1040 Stove User Manual


 
Installation
MASONRY FIREPLACE INSTALLATION - INSERT:
Unless you are experienced, we recommend installation by your dealer or a
professional installer.
It is recommended that you install the decorative plates (if purchased) into the shrouds
before installing the unit. Refer to “INSTALLATION OF DECORATIVE PLATES - INSERT.
Install only in a masonry replace at least 25” (635 mm) wide, 22” (560 mm) high and 14” (356 mm)
deep with a good-condition chimney at least 15 ft (4.6 m) high, both of which have been constructed in
accordance with the building code. Be sure the replace and chimney are clean and sound without any
cracks or loose mortar. Do not remove any bricks or mortar from the replace.
If there is a combustible oor in front of
the masonry replace, the replace insert
must be 8” (203 mm) above the combustible
oor, and oor protection must be provided
18” (457 mm) in front of the replace insert
and 8” (203 mm) to each side of the unit.
Refer also to SPECIFICATIONS - CLEARANCES TO
COMBUSTIBLES - 1200 INSERT and SPECIFICATIONS
- CLEARANCES TO COMBUSTIBLES - 1700 INSERT.
1. Remove any replace damper or fasten in
a permanent open position.
2. (IN CANADA) The stove is vented with
a 6” stainless steel liner that goes directly to
the top of the chimney and is covered with
a rain cap. The chimney top is sealed with
a ashing or steel plate that supports the
weight of the chimney liner. The installation
must conform to the liner’s manufacturer’s
instructions.
This replace must be installed with a
continuous liner of 6” diameter (CANADA
ONLY) extending from the replace insert to
the top of the chimney. The chimney liner
must conform to the class 3 requirements of
ULC-S635 Standard for Lining Systems for
Existing Masonry or Factory-Built Chimneys
and Vents, or ULC-S640 Standard for Lining
Systems for New Masonry Chimneys.
(IN U.S.A.)The appliance when installed,
must follow local building codes, in the
absence of local building codes, with the
current NFPA 211 Standard for Chimneys,
Fireplaces, Vents, and Solid Fuel-Burning
Appliances.
Floor
Protection
Combustible Floor
Masonry Fireplace
8"
(203 mm)
Rain Cap
Steel Plate or Flashing
Flexible or Rigid 6"
Stainless Steel Liner
Mantel
Top Facing
Damper Removed
or Fastened Open
Sheet Metal Screws
Fastening Collar to
Stainless Steel Liner
Surround Panel
USA 16” (406 mm)
CND 18” (450 mm)
Figure 31: Insert Installation into existing replace with
hearth.
30