Emerson Rosemount 2230 Water Heater User Manual


 
Reference Manual
300560EN, Rev AA
May 2011
Rosemount 2230
www.rosemount-tg.com
Appendix A Reference Data
A.1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1
A.2 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . page A-3
A.3 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . page A-4
A.1 SPECIFICATIONS
General
Product Rosemount 2230 Graphical Field Display
Toggle time The time each value or set of values are shown on the display: 2-30 s
Language selection possibilities English, French, German, Spanish, Italian, and Portuguese
Variables to display Level, level rate, ullage, signal strength, volume (TOV), liquid average temperature,
1-16 spot temperature, vapor average temperature, ambient temperature, free water
level, vapor pressure, liquid pressure, air pressure, observed density, and flow rate
Units to display Level, free water level, and ullage: meter, millimeter, feet, or imperial 1/16
Level rate: meter/second, meter/hour, feet/second, or feet/hour
Flow rate: meter
3
/hour, liter/minute, feet
3
/hour, barrel/hour, or US gallon/hour
Total Observed Volume (TOV): meter
3
, liters, feet
3
, barrel, or US gallon
Temperature: °F, °C, or °K.
Pressure: psi, psiA, psiG, bar, barA, barG, atm, Pa, or kPa
Density: kg/m
3
, kg/liter, or °API
Signal strength: mV
Hazardous location certifications and IS
parameters
ATEX, FM-C, FM-US, and IECEx.
CE-mark Complies with applicable EU directives (EMC, ATEX)
Ordinary location certification Complies with FM 3810:2005 and CSA: C22.2 No. 1010.1
Electric
Power supply Powered by Rosemount 2410 Tank Hub (9.0-17.5 VDC, polarity insensitive)
IS parameters See “Product Certifications” on page B-1
Bus current draw 30 mA
Display type Back-lit LCD monochrome display. 128x64
Start-up time 5 s
Update rate New values to display once every two seconds
Response time < 0.5 s from released button to new image
Cable entry
(1)
(connection/glands) Three entries, two M20×1.5 and one M25×1.5.
Optional:
• ½ - 14 NPT conduit / cable adapter
• Metal cable glands (½ - 14 NPT)
• 4-pin male Eurofast connector or A size Mini 4-pin male Minifast connector
Tankbus cabling AWG 0.5-1.5 mm
2
(22-16), shielded twisted pairs
Built-in termination Yes (to be connected if required)
Mechanical
Housing material Polyurethane-covered die-cast aluminum
Dimensions (width x height x depth) 150 x 120 x 78 mm (5.9 x 4.7 x 3.1 in.)
Weight 1.2 kg (2.6 lbs)