3. Point remote control toward the lower
front of replace and push both buttons
at the same time. Hold for 6 seconds. The
gas valve will open and electronic igni-
tion will begin sparking to light the pilot.
Note: You will be able to hear a clicking
sound during this process. LED on wall
switch will light.
Note: You may be running this heater for
the rst time after connecting to gas supply
or at the start of your heating season. If
so, the ON button may need to be pressed
again. This will allow air to bleed from gas
system. If several attempts to light pilot fail,
contact a qualied service person or gas
supplier for repairs. Until repairs are made,
light and operate manually (see Manual
Lighting Instructions for Electrical Power
Outage).
4. When pilot ame is lit, the thermocouple is
heated by the ame. When thermocouple
becomes hot (5 to 15 seconds), main burner
will automatically light on high ame.
5. To lower ame, point remote control toward
lower front of replace and push HI/LO
button once.
Note: This replace does not have a pilot-
only mode.
TO TURN OFF GAS


Push ON/OFF button on wall switch once.

Control
Point remote control toward lower front of re-
place and push both buttons at the same time.
MANUAL LIGHTING
INSTRUCTIONS FOR

OUTAGE
-

-


OPERATING FIREPLACE
Continued






Because this replace has an electronic ignition
system, in the event there is a loss of power, it
will be necessary to manually light the pilot with
the piezo ignitor. After the pilot is lit, the main
burner will light automatically.
1. Follow steps 1 through 3 under Normal
Lighting Instructions, page 26.
2. Set manual ignition bypass switch on con-
trol panel to ON position (manual ignition
position). See Figure 50.
3. The pilot is attached to the rear of the front
burner. You will be able to see the pilot
and spark electrode without removing the
screen or logs.
4. Place the magnetic manual override handle,
provided with this unit, on the end of the
gas valve stem (see Figure 50).
5. Turn the override handle fully counter-
clockwise to the PILOT position.
The handle will not stop but will begin
to slip when you have fully turned to the
PILOT position.
6. While holding the valve handle in the
PILOT position, press and release piezo
ignitor button (see Figure 50). This will light
the pilot. If needed, keep pressing ignitor
button until pilot lights.
Figure 50 - Control Locations
Manual Ignition
Bypass Switch
(Down is ON)
Magnetic
Manual
Override
Handle
ON/OFF
Button
HI/LO
Button
Piezo Ignitor
Wall
Switch
Gas
Valve
LED
LED