www.desatech.com
111245-01C10
3. Remove screws that attach replace oor as-
sembly to replace. Open lower louver door.
Carefully lift up replace oor assembly and
remove from replace, taking care to pull
exible gas line through the access holes (see
Figure 6). Note: Be careful of all wires on
underside of log base.
-
INSTALLATION
Continued
Figure 6 - Removing Fireplace Floor
Assembly
Screws
Fireplace Floor
Assembly
Flexible Gas Line
ELECTRICAL CONNECTIONS FOR
This fireplace operates on 120 VAC, 60 Hz
power. An electrical power cord is supplied with
this unit.
For Mantel Installation
1. Determine from which side of the replace the
power cord will exit. Locate the 1.5" diameter
hole near the center of oor support bracket on
appropriate side of lower cavity (see Figure 7).
2. Locate power cord. Remove wire tie or tape
holding plug end of power cord.
3. Power cord has 2 plastic hole bushings
threaded onto it. Route cord’s 3-prong plug
through the 1.5" diameter hole in appropriate
oor support bracket.
4. Push rst plastic bushing completely through
hole. Squeeze bushing as needed to do this.
5. Install the second plastic bushing into the
hole in the oor support bracket by snapping
into place.
6. Route the 3-prong plug through the 1.5" hole
in replace outer casing.
7. Install the rst plastic bushing into this hole
by snapping into place.
8. After you have connected to gas supply and
checked your gas connections (see pages 17
through 20), plug power cord into any conve-
nient 3-prong grounded wall receptacle near
replace.
For Recessed Installation
If an outlet is not installed in replace, install
model GA3555 - Outlet Kit with Cover. This
kit will supply a convenient 3-prong grounded
electrical outlet for power. Refer to installation
manual provided with this optional accessory for
instructions on wiring. Note: A qualied installer
must make all electrical connections.
RELOCATING WALL SWITCH
Note: The decorative wall switch plate supplied
is white. The wall switch plate may be painted to
match your decor.
The push-button switch and decorative wall
plate assembly supplied with your replace is
pre-mounted at the factory in the lower cavity of
the replace. You may relocate this wall switch
assembly to a more convenient location such as the
side of your mantel or directly onto the wall near
the replace. To mount the wall switch assembly,
you must rst cut openings in the mantel or wall
where the switch will be located.
Figure 7 - Routing Power Cord
Power
Cord
Bushings
Hole in Floor
Support Bracket
Hole in Outer
Casing