www.desatech.com
111245-01C16
INSTALLATION
Continued
WARNING: Failure to connect
may cause electrical short circuit
electrician should check that all
12. Plug in blower power cord.
a. If your firebox is installed as a free-
standing unit with an accessory mantel,
determine whether the power cord will
exit the left side or the right side of the
rebox. Install one plastic bushing provided
into the 1
1
/
2
" hole in the oor support on
the exit side. Install the second bushing
provided into the 1
1
/
2
" hole in the outer
casing through which the power cord will
exit (see Figures 21 and 22). Route power
cord through plastic bushings and plug the
power cord into a properly grounded three-
prong wall receptacle near the rebox.
b. If your replace system installation is
recessed and if an outlet is not installed in
your replace, you must install the GA3555
Outlet kit with cover in your replace which
will supply a convenient 3-prong grounded
electrical outlet for your blower. Refer to the
installation manual provided with the model
GA3555 accessory for instructions on wiring
the duplex outlet. Note: A qualied installer
must make all electrical connections.
13. Check to make sure that the power cord and all
wires are completely clear of the blower wheel
and that there are no other foreign objects in
blower wheel.
CAUTION: Never touch the
14. Peel off backing paper and stick supplied
wiring diagram decal near center of rebox
bottom (see Figure 23).
15. If gas connections have been made and
checked, replace replace oor assembly in
replace. Feed exible gas supply line into
replace base area while replacing replace
oor assembly. Make sure the entire exible gas
line is in replace base area. IMPORTANT: Do
not pick up replace oor assembly by burners.
This could damage burners. Only handle base
by grates. Note: Be careful of all wires and
components on underside of oor assembly.
Figure 21 - Installing Plastic Bushing for
Power Cord (Right Side Exit Shown)
Right Floor
Support
Bracket
Plastic
Bushing
Figure 22 - Installing Bushings
(Left Side Exit shown)
Bushing Location for
Recessed Installation
Bushing
Location for
Freestanding
Installation
Plastic
Bushing
V
a
r
i
a
b
le
F
a
n
S
w
it
c
h
W
h
i
t
e
W
h
i
t
e
B
l
a
c
k
G
r
e
e
n
O
n
1
1
0
/
1
1
5
V
.
A
.
C
.
Blower
Moto
r
B
l
a
c
k
B
l
a
c
k
B
l
a
c
k
O
f
f
Figure 23 - Location of Wiring Diagram
Decal 3" from Blower
Wiring
Diagram
Red
Variable
Fan Switch
Fan Switch
(N.O.)
Green
White
On
110/115
V.A.C.
Blower
Motor
Black
Off
1
2
Black
Blue