CAUTION: Use only new,
     -


     




Installation must include an equipment shutoff
valve, union and plugged 1/8" NPT tap. Locate
NPT tap within reach for test gauge hook up.
NPT tap must be upstream from replace (see
Figure 24).
IMPORTANT: Install equipment shutoff valve
in an accessible location. The equipment shutoff
valve is for turning on or shutting off the gas to
the appliance.
Check your building codes for any special re-
quirements for locating equipment shutoff valve
to replaces.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could result
in clogged replace valves. Never use sealant on
are threads.
    


Figure 24 - External Regulator with Vent
Pointing Down
Propane/LP
Supply Tank
External
Regulator
Vent
Pointing
Down
Figure 25 - Gas Connection
* Purchase the optional CSA design-certified
equipment shutoff valve from your dealer. See
Accessories, page 40.
Natural
From Gas
Meter
(5" W.C. to
10.5" W.C.
Pressure)

From External
Regulator (11"
W.C. to 14 "
W.C. Pressure
CSA Design-Certied
Equipment Shutoff Valve
With 1/8" NPT Tap*
3" Minimum
Sediment Trap
Pipe Cap Tee
Nipple Joint
INSTALLATION
Continued
We recommend that you install a sediment trap in
supply line as shown in Figure 25. Locate sediment
trap where it is within reach for cleaning. Install in
piping system between fuel supply and replace.
Locate sediment trap where trapped matter is not
likely to freeze. A sediment trap traps moisture and
contaminants. This keeps them from going into re-
place gas controls. If sediment trap is not installed or
is installed wrong, replace may not run properly.


Installation Items Needed
5/16" hex socket wrench or nut-driver
Phillips screwdriver
sealant (resistant to propane/LP gas, not
provided)
1. If replace screen and oor are still installed,
see Removing Fireplace Screen and Floor
Assembly, page 9.
2. Route gas line (provided by installer) from
equipment shutoff valve to replace. Route
exible gas supply line through one of the
access holes.

-

    

-

