SAFETY INFORMATION
- The Inglenook gas log kit is designed to be installed only in an Inglenook solid-fuel burning fireplace
that has a working flue constructed of noncombustible materials.
-
Maintain a minimum permanent free flue opening of 50.2 square inches provided by the Inglenook
fireplace chimney and chimney damper system to vent flue gasses. Maintain this permanent free flue
opening by keeping the damper in the fully open position during gas log use. See FIGURE 2.
-
Solid fuels will not be burnt in the Inglenook fireplace while the Inglenook gas log set is installed.
-
The Inglenook fireplace damper is to remain the open position, see FIGURE 2, at all times during the
use of the Inglenook gas log set. Attach a damper clamp as shown in this manual.
-
A fireplace screen must be in place at all times when operating the Inglenook gas logs. The
Inglenook combustion air vent is to be installed and open during gas log burning.
-
The Inglenook and the Inglenook gas valve is to be disconnected from the gas supply line during any
gas supply system testing where test pressures exceed ½ pounds per square inch gauge (psig) (3.5
kPa).
-
Do not use the Inglenook gas log system if any part of the system has been under water. Immediately
contact a certified service technician to inspect the appliance. Replace any part(s) of the control
system or the gas valve that has been under water.
-
Do not store or use gasoline or other flammables near this appliance.
-
Do not place clothing or flammable material on or near this appliance.
-
Due to high operating temperatures, this appliance should be located out of high traffic areas and
away from furniture and draperies.
-
Children and adults should be alerted to the hazards of high surface temperatures. Maintain safe
clearances (stay away) to avoid burns or clothing ignition.
-
Always supervise young children playing in the same room as this operating appliance.
-
Any safety screen, guard or other parts removed for servicing this appliance must be replaced prior to
operation.
-
A CERTIFIED GAS TECHNICIAN SHOULD PERFORM INSTALLATION AND REPAIR.
ONCE INSTALLED, AN ANNUAL INSPECTION NEEDS TO BE PERFORMED BY A
CERTIFIED GAS PROFESSIONAL.
-
The interior of a gas stove is subject to surface rust due to moisture in the combustion air as well as
condensation created during the initial warm up and firing of the gas appliance. At a minimum,
annually clean and repaint the interior surfaces of the firebox to prevent deterioration. More frequent
cleaning may be required due to carpet lint, bedding material, dust, etc. being drawn into the
appliance. It is imperative that this appliance’s control compartment, burners, circulating air system
is kept clean.
-
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR
MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS
MANUAL FOR ASSISTANCE OR FOR ADDITIONAL INFORMATION CONSULT A
QUALIFIED INSTALLER, SERVICE AGENCY, OR GAS SUPPLIER.
-
ALWAYS use high temperature rated silicone or sealing compound at 600
O
F (316
O
C) or higher.
-
The Inglenook gas logs are designed to operate with the doors fully open or fully closed.
-
WARNING: AN INGLENOOK GAS LOG KIT IS DESIGNED FOR A VENTED INGLENOOK
FIREPLACE WITH AN 8 INCH DIAMETER CHIMNEY PIPE A MINIMUM OF 8 FEET TALL
TO A MAXIMUM OF 50 FEET TALL. REFER TO PAGE 32 AND 33 OF THE INGLENOOK
OWNER’S MANUAL FOR PROPER CHIMNEY INSTALLATION.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE