Version 1.0b
10
discrepancy or to obtain necessary parts to replace any missing or damaged components. TABLE 2
provides a gas log kit part’s list for both natural gas and propane kits. Use the appropriate version of
TABLE 2 as a check sheet while verifying the presence and condition of each kit part. Again, contact
Country Flame or an authorized dealer to resolve any issues before converting the Inglenook gas log set to a
different fuel.
LIQUID PROPANE CONVERSION KIT
ITEM QTY PART NUMBER
ITEM DESCRIPTION
Regulator 1
GC-3905-01
SIT 820 NOVA mV Gas Valve
Pilot 1
BV-4613
#51 DMS Pilot Injector Orifice
Front Spud Orifice 1
IN-6513
#31 DMS NG Front Orifice Spud
Rear Spud Orifice 1
IN-6514
#43 DMS NG Rear Orifice Spud
Conversion Label 1
IN-6521
Conversion LP to NG
Instructions 1
IN-6523
Conversion Kit Instructions
TABLE 2a: IN-6504 CONVERSION KIT (to natural gas)
NATURAL GAS CONVERSION KIT
ITEM QTY PART NUMBER
ITEM DESCRIPTION
Regulator 1
GC-3906-01
SIT 820 NOVA mV Gas Valve
Pilot 1
BV-4614
#35 DMS Pilot Injector Orifice
Front Spud Orifice 1
IN-6515
#48 DMS LP Front Orifice Spud
Rear Spud Orifice 1
IN-6516
#55 DMS LP Rear Orifice Spud
Conversion Label 1
IN-6522
Conversion NG to LP
Instructions 1
IN-6524
Conversion Kit Instructions
TABLE 2b: IN-6503 CONVERSION KIT (to propane)
It should be noted that conversion from one type of fuel to another type of fuel requires the adjustment of
both the front and rear burner air shutters. Refer to the specifications in this manual and verify local codes
and other site-specific conditions to ensure proper setting of all parameters involved in the fuel conversion
process.
ALTITUDE LIMITATIONS
In the United States, the Inglenook gas log input ratings are determined at sea level operation. The
Inglenook gas logs do not require any operational changes up to and including 610 meters. Gas log
operations above 610 meters require the Inglenook burners to be set as stated in TABLE 3. Exception: As
permitted by the authority having jurisdiction.
Canadian input ratings of this unit are determined at seal level operation. No Inglenook input rating needs
to be change up to 4,500 feet above sea level in Canada. Installation of the Inglenook gas logs at altitudes
above 4,500 feet is subject to field test of the individual installation and approval by the local authority
having jurisdiction.