Version 1.0b
23
CHECK VENT SYSTEM
FREQUENCY: Once during annual inspection. See General Vent Inspection.
PERFORMED BY: Qualified service technician or homeowner.
TASK PERFORMED: Check complete vent system for corrosion, moisture problems, pinholes or
broken seals. Remove chimney cap and inspect vent and cap for debris.
Ensure clean and open vent system.
GENERAL INSPECTIONS
GENERAL VENT INSPECTION
Inspect the venting system periodically. Additional areas to inspect are as follows:
1. Check areas of the venting system that are exposed to the elements for corrosion. These will appear
as rust spots or streaks, and in extreme cases, can be holes. These components must be replaced to
ensure the integrity of the system and the safety of the homeowner.
2. Remove the chimney cap and shine a flashlight down the vent. Remove all debris, bird nests, or
other foreign material found in the vent system.
3. Check for evidences of excessive condensate, such as water droplets forming in the inner liner, and
subsequently dripping out of vent joints. Continuous condensate can cause corrosion of caps, pipe
and fittings. Condensation may be caused by having excessive horizontal runs, too many elbows,
and exterior portions of the system being exposed to cold weather. Consult a certified professional
to correct.
4. Inspect joints, to verify that no pipe sections or fittings have been disturbed or consequently
loosened. Also, check mechanical supports such as wall straps or plumbers' tape for proper
integrity/support.
5. For all direct vent systems, proper re-assembly and resealing of the vent-air intake system is
mandatory. If the vent-air system is disassembled for any reason, reinstall each part per instruction
provided for the initial installation.
GENERAL CLEANING REQUIREMENTS
Routinely perform general cleaning of the Inglenook to remove all dust, lint, or other debris that has built
up during non-use or in the off-season. Clean the two burners per the specific tasks listed in this manual.
Blow out the burners with dry air or carefully vacuum the burners to remove dust or other debris. If any
burner damage or degradation is noted, contact a certified professional to verify their working order. No
lubrication of any part is required in the Inglenook gas log system.
Country Flame recommends that at a minimum, a certified professional conduct an annual inspection of the
venting system. At no time should the Inglenook’s combustion air or ventilation air become obstructed.
Free airflow is crucial to proper Inglenook operation. The pilot and burner flame patterns require
inspection. Flame patterns should not appear suspended above the pilot tube or the burner surfaces. Nor
should the pilot or burner flame appear lifeless or smoky in their burn pattern. Have the operational burn
patterns checked by a certified professional in the event there is any question about gas burn patterns. Do
not use the Inglenook if any part or component of this appliance has ever been under water. Immediately
call a certified professional to inspect or replace any part or control system that has been under water.
GENERAL SAFETY
-Always shut off the gas supply and allow the heater to cool down before attempting any service work.
-Always check for gas leaks, after servicing. Do not use a flame to check for gas leaks.
-Always check for correct combustion and ventilation airflow after performing any service.
-Always make sure the heater is away from any combustible or flammable materials.
-Always ensure proper re-assembly and re-sealing of all vent-air intake parts. If any part of the system is
disassembled, reinstall those parts per the instructions provided in this manual.