Chicago Electric 65712 Garage Door Opener User Manual


 
SKU 65712 For technical questions, please call 1-800-444-3353. Page 22
Setting Opening Force:
Figure BB Figure CC
12. Press and hold the “SET” Button for more than four seconds. Repeatedly press
the “UP” Button until the Digital Display indicates “3”. Press and release the
“SET” Button. The Digital Display will indicate a ashing “3”. Now the unit will
enter into a Force Adjustment mode. (See Figures BB and CC.)
(1-9)
Figure DD
(9-1)
Figure EE
13. Press and release the “UP” Button. The Digital Display will show a ashing
“1” - “9” (default value is “4”) which indicates the open force level. “1” is the
minimum force, and “9” is the maximum force. Each time you press and release
the “UP” Button, the gure increases by 1, and the force increases to a higher
level. Each time you press and release the “DOWN” Button, the gure decreases
by 1, and the force decreases to a lower level. (See Figures DD and EE.)
Figure FF Figure GG
14. Press the “SET” Button to store the data when the desired open force is set. The
Digital Display will indicate a steadily glowing “3”. The unit is ready for setting
another parameter. If no other setting is to be programmed right now, press the
“SET” Button. The Digital Display will indicate “H”. Now the open force adjust-
ment is nished. (See Figures FF and GG.)