New Buck Corporation CDVB200 Stove User Manual


 
OPERATING STOVE
WITH BURNER SYSTEM
FOR YOUR SAFETY
READ BEFORE
LIGHTING
A. This appliance has a pilot which
must be lighted by hand. When
lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING smell all
around the appliance area for gas.
Be sure to smell next to the floor
because some gas is heavier than air
and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
If you cannot reach your gas
supplier, call the fire department.
C. Use only your hand to push in or
turn the gas control knob. Never use
tools. If the knob will not push in or
turn by hand, don’t try to repair it,
call a qualified service technician.
Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part
has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been
under water.
WARNING: If you do not follow these
instructions exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
LIGHTING
INSTRUCTIONS
1. Stop! Read the safety information
in column one.
2. “Set the thermostat to lowest.”
3. “Turn off all electric power to the
appliance.”
4. Open access cover door.
5. Turn control knob clockwise___
to the “OFF” position.
NOTE: Knob cannot be turned from
“PILOT” to “OFF” unless knob is
pushed in slightly.
6. “Wait five (5) minutes” to clear
out any gas. Then smell for gas,
including near the floor. If you
smell gas, STOP! Follow “B” in
the safety information label. If
you don’t smell gas, go to the next
step.
7. Pilot is located between the front
and rear burner.
8. Turn control Knob counter
clockwise ____ to the “Pilot”
position.
9. Press in control knob. With
control knob pressed in,
immediately push and release
ignitor button. This will light the
pilot.
NOTE: *If the control knob does not
pop up when released, “Stop” and
immediately call your service
technician or gas supplier.
*If the pilot will not stay lit after
several tries, turn the gas control knob
to “OFF” and call your service
technician or gas supplier.”
10. Continue to hold the control knob
pressed in for one (1) minute after
the pilot is lit. Release the control
knob and it will pop back up. Pilot
should remain lit. If it goes out,
repeat steps 5 thru 10.
11. Turn control knob counter
clockwise ____ to “ON” position.
12. Close access cover door.
13. Turn on all electric power to the
appliance.
14. If using unit without wall
thermostat place (AUTO/OFF/
MANUAL) switch in the
“MANUAL” position. If using
wall thermostat place (AUTO/
OFF/MANUAL) switch in the
“AUTO” position, and place wall
thermostat to a setting higher
than room temperature.
TO TURN OFF GAS
TO APPLIANCE
1. Set the thermostat to lowest
setting (if used).
2. Turn off all electric power to the
appliance if service is to be
performed.
3. Open access cover door.
4. Push in gas control knob slightly
and turn clockwise _____ to
“OFF”. Do not force.
5. Close access cover door.
MANUAL LIGHTING
PROCEDURE
1. Remove glass door (see Removing/
Replacing Glass Door, page 18).
2. Follow steps 1 through 8 under
Lighting Instructions.
3. Depress gas control knob and light
pilot with match.
4. Keep gas control knob pressed in
for one (1) minute after lighting
pilot. After one (1) minute, release
gas control knob. Now follow steps
10 through 14, column 2.
5. Replace glass door (see Removing/
Replacing Glass Door, page 18).
Sit Millivolt Valve
Variable
Flame Control
Knob
Gas Control
Knob
Figure 40– Gas Valve & PIEZO IGNI-
TOR
PILOT
Pilot Burner
Ignitor Electrode
Thermocouple
Thermopile
PIEZO IGNITOR BUTTON LO-
CATED TO THE LEFT, BESIDE
THE SIDE OF THE GAS VALVE
21