New Buck Corporation CDVB200 Stove User Manual


 
Continued
Pressure Testing Burner System Gas
Connections
1. Open equipment shutoff valve (see
Figure 33 page 16).
2. Open propane/LP supply tank valve
for propane/LP burner system or main
gas valve located on or near gas meter
for natural gas burner system.
3. Make sure control knob of burner
system is in the OFF position.
4. Check all joints from equipment
shutoff valve to thermostat gas valve
(see Figure 34 for propane/LP or
Figure 35 for natural). Apply
commercial leak test solution to all gas
joints. Bubbles forming show a leak.
Correct al leaks at once.
5. Light burner system (see Operating
Stove with Burner System, pages 21
through 22). Check all other internal
joints for leaks.
Equipment Shutoff Valve
Propane /LP Supply
Tank
Gas Valve Location
Figure 34– Checking Gas Joints for Propane/LP Gas Burner System
CONTROL VALVE LOCATION
EQUIPMENT
SHUTOFF
VALVE
GAS METER
Figure 35– Checking Gas Joints for Natural Gas Burner System
17