PHASE RESEARCH
USER GUIDE
SECTION 13 - PARAMETERS PROGRAMMING 13-23
SECTION 13 - PARAMETERS
13-1.9 Set Remote Addressing
IF IT IS NECESSARY TO CHANGE A REMOTE DISPLAY’S ADDRESS,
USE THE FOLLOWING STEPS:
1. Unplug the five-pin connector from the top of the Remote Display and remove
the display from its mounting. Remove the two (2) smaller Phillips head
screws from the top of the Display first, and then remove the two (2) Phillips
head screws from the bottom of the Display. The two (2) covers of the Display
should now separate.
2. After separating the two covers, locate the eight (8) position dip-switch block
located on the upper right-hand side of the circuit board. Adjust the switches
according to the addresses you want.
Remote Display Address Dip-Switch Settings
3. Plug the connector back into the Remote Display and verify that it has the cor-
rect address before reassembling.
4. Once the Remote Display is addressed correctly, reassemble and remount it.
8
7
6
5
4
3
2
1
O
N
Address 001:
Address 002:
Address 003:
Address 004:
Address 005:
Address 006:
Switch 1 ON, 2 OFF, 3 OFF
Switch 2 ON, 1 OFF, 3 OFF
Switches1&2ON,3OFF
Switch 3 ON, 1 OFF, 2 OFF
Switches1&3ON,2OFF
Switches2&3ON,1OFF
OFF