Weber 5500 Burner User Manual


 
25
Step 21
Purge air from gas lines
You will need: one burner control knob and FlameCheck
button.
It is necessary to bleed the air out of newly installed gas
lines. Turn gas supply ON at the source. Put on the
FlameCheck button and the front burner control knob.
Push the front burner control knob down and turn to HI.
Push FlameCheck button down and hold down to bleed
the air from lines. When you start to smell gas, release
FlameCheck button and turn front burner control knob to
OFF. Figure 25.
ƽ DANGER ƽ
Be sure there are no sparks or open
flames in the area while purging. This
can cause fire, explosion or serious
bodily injury.
Figure 25
Step 20
Install igniter
Note - The igniter wires are already attached to the Gas
Catcher Ignition Chamber and the igniter. This was done
to factory test the ignition system.
The igniter lock nut is on the igniter.
Insert the top of the igniter up through the large part of
the key hole in the frame brace. Loosen the igniter lock
nut and slide the igniter into the small part of the keyhole.
Tighten the igniter lock nut. Figure 24.
Note - If the igniter works loose, carefully tighten the
igniter lock nut with an adjustable wrench or pliers.
Figure 24
Igniter lock nut
Key hole in
frame brace
Small part of
keyhole in
frame brace
Frame brace
Frame brace
(a)
(b)
(c)