Weber 5500 Burner User Manual


 
24
Figure 23
Step 19
Check that all burner valves are off
You will need: one burner control knob.
(Valves are shipped in the OFF position, but you should
check to be sure.) Put the knob on each valve. Check by
pushing down and turning clockwise. If they do not turn
they are off, proceed to the next show. Figure 23.
Step 18
Connect barbecue gas supply line to the natural
gas supply
Note - We recommend that the connection between
the barbecue gas supply line and the natural gas
supply be flare to flare. A 3/8-inch flare fitting has
been included with the barbecue gas supply line of
your Perma-Mount Gas Barbecue. The fitting is
loosely connected for shipping and should be
removed before installation.
You will need: barbecue gas supply line, 3/8 inch flare
fitting, 3/4 inch and 11/16 inch wrenches.
ƽWARNING: This barbecue is NO
T portable. It
must be bolted down at all times when it is
connected to a natural gas supply.
Unscrew the 3/8 inch flare fitting from the barbecue gas
supply line. Screw the pipe fitting end of the 3/8 inch
flare fitting into the natural gas supply pipe. Tighten with
an 11/16 inch wrench. Figure 22 (a).
Attach the flare nut on the barbecue gas supply line to
the flare fitting end of the 3/8 inch flare fitting. Tighten
with a 3/4 inch wrench. Figure 22 (a).
Attach the flare nut at the other end of the barbecue gas
supply line to the manifold fitting. Finger tighten only. Hold
the supply line against the upright frame crosspiece and
tighten the fitting at the manifold using the 3/4 inch wrench.
Figure 22 (b).
Figure 22
(a)
(b)
Natural Gas
Supply Pipe
Pipe fitting end of
3/8-inch Flare Fitting
Flare fitting end of
3/8-inch Flare Fitting
Barbecue gas
supply line