38
Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need.
You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at www.wayne-dalton.com
❉
Erasing Remote Controls:
CAUTION:
MANUALLY DISCONNECT THE DOOR FROM OPENER
USING THE EMERGENCY DISCONNECT HANDLE PRIOR TO ERASING
REMOTE CONTROLS.
To clear programming of all remote control devices, press and hold
the opener’s red program button for approximately 10 seconds.
When the opener beeps 3 times, all remote controls are erased.
Multi Opener Light Control:
A single light fixture can be controlled by up to 6 openers. Follow
the procedure outlined on Step 23 to program additional openers.
Erasing Light Fixtures:
To clear programming of all openers from a light fixture, press
and hold the light fixture program button for approximately 10
seconds. When the light fixture lamp and LED flash 3 times, all
openers are erased.
Maintenance
Customizing the Settings (Continued)
Program Button
Red
Program
Button
❉
Monthly Maintenance:
1. Lubricate hinges and rollers of garage door.
2. Inspect the door for loose fasteners, worn or frayed
counterbalance cables and the presences of legible safety labels/
tags. Have repairs made by a qualified service person.
Contact customer assistance for safety labels/ tags.
3. With door fully closed, move the emergency disconnect to the
manual door operated position and manually operate door. If the
door feels unbalanced or binds, have a qualified service person
make necessary adjustments or repairs to the door.
4. Perform the contact/obstruction tests. See Steps 28 and 29 for
the contact/obstruction test instructions. If Door/Opener fails
Contact/Obstruction test run profile routine Steps 24 or 25
making sure door is completely closed prior to activation. If
opener still fails, have a qualified service person make
adjustments/repairs or this could result in severe or fatal injury.
5. Failure of Door/Opener to respond to transmitter or wall station
may be due to a weak or dead battery. Replace the battery.
Battery replacement for Wall Station:
Remove the battery cover completely (right-hand side of wall
station) by disengaging the battery cover’s lower clip. Install two
AAA batteries into the wall station observing the polarity, (+) and (-),
of both batteries. After a few seconds, the red LED will begin to
blink every three seconds. If it is desired to slow the red LED blink
rate refer to the wall station operation section on page 34 “Backlit
LED Light”. Re-install the battery cover by first inserting its top into
the wall station then inserting and securing its bottom.
Note: Use only 2 AAA batteries.
Battery replacement for Transmitter:
Insert a coin in the coin slot of the transmitter and twist coin to
access the dead battery. Replace the battery, being careful to match
the positive (+) symbols on the circuit boards with the battery.
Note: Use (1) CR2016 or equivalent battery.
Note: Dispose of dead battery properly.
OPERATION