Toshiba RAV-SP300AT2-UL Air Conditioner User Manual


 
– 99 –
No.
Part name
Discharge
port cabinet
Side cabinet
Procedure
1. Detachment
1) Perform work of Detachment 1 of
.
2) Remove screws for the discharge port
cabinet and the partition board.
(M4, 8 mm, 4 pcs.)
3) Remove screws for the discharge port
cabinet and the bottom plate.
(Hexagonal screw M4, 10 mm, 2 pcs.)
4) Remove screws for the discharge cabinet
and the motor base. (M4, 8 mm, 2 pcs.)
5) Remove screw for the discharge cabinet
and the heat exchanger. (M4, 8 mm, 1 pc.)
6) Remove screws for the discharge port
cabinet and the fin guard.
(Hexagonal screw M4, 10 mm, 2 pcs.)
1) Perform work of Detachment 1 of
.
2) Remove the screws which fix the inverter
assembly and the side cabinet.
(M4, 8 mm, 2 pcs.)
3) Take off screws that fix the wiring division
panel and the side cabinet.
4) Remove the screws for the side cabinet
and the valve fixing plate.
(M4, 8 mm, 2 pcs.)
6) Remove screws for the side cabinet and
the piping panel (Rear).
(Hexagonal screw M4, 10 mm, 2 pcs.)
6) Remove screw for the side cabinet and the
bottom plate.
(Hexagonal screw M4, 10 mm, 1 pc.)
7) Remove screws for the side cabinet and
the fin guard (Heat exchanger).
(Hexagonal screw M4, 10 mm, 5 pcs.)
Remarks
Inverter
protective
cover
1) Perform work of Detachment 1 of
.
2) Take off screw which fixes the inverter
assembly and the inverter protective cover.
(M4, 8 mm, 1 pc.)
Valve fixing plate
Valve fixing plate
Inverter assembly
Inverter assembly
Side cabinet
Side cabinet
Valve fixing plate
Inverter assembly Side cabinet
Fin guard
Inverter protective cover
Partition boardMotor base
Heat exchanger Discharge