– 9 –
<C
ooling> RA
S
-M18EAV-E , RA
S
-M18EA
C
V-
E
O
peration
m
o
de
Volt
s
Operation
S
tatu
s
Operating indoo
r
u
nit
U
nit capacit
y
(
kW
)
C
apacit
y
(
kW
)
R
unning curren
t
P
ower Consumptio
n
V
A
B
A
B
kW
A
W
C
ooling
220
1
u
nit
10
–
2.7
–
2
.7
(
1.1 to 3.2
)
3.03
(
1.43 to 3.83
)
6
00
(
220 to 800
)
13
–
3
.7
–
3
.7
(
1.1 to 4.2
)
5
.
10
(
1.43 to 6.49
)
1100
(
220 to 1400
)
16
–
4
.
5
–
4.
5
(
1.1 to 4.9
)
6
.
96
(
1.43 to 7.88
)
1
500
(
220 to 1700
)
2 unit
s
10
10 2.55 2.55 5.1
(
1.4 to 6.1
)
7
.19
(
1.69 to 9.97
)
1550
(
260 to 2150
)
13
10
2
.
85
2
.
35
5
.
2
(
1.4 to 6.2
)
7.
42
(1.69 to 10.06
)
1600
(
260 to 2170
)
1
31
3
2.60 2.60 5.2
(
1.4 to 6.2
)
7.42
(
1.69 to 10.06
)
1600
(
260 to 2170
)
16
10 3.25
1
.95 5.2
(
1.4 to 6.2
)
7.42
(
1.69 to 10.06
)
1600
(
260 to 2170
)
230
1 un
i
t
10
–
2
.7
–
2
.7
(
1.1 to 3.2
)
2
.
90
(
1.37 to 3.66
)
600
(
220 to 800)
13
–
3
.7
–
3
.7
(
1.1 to 4.2
)
4.
88
(
1.37 to 6.21
)
11
00
(
220 to 1400
)
16
–
4
.5
–
4.5
(
1.1 to 4.9
)
6.65
(
1.37 to 7.54
)
1500
(
220 to 1700
)
2
u
nit
s
10
10
2
.
55
2
.
55
5
.
1
(
1.4 to 6.1
)
6
.
88
(
1.61 to 9.54
)
1550
(
260 to 2150
)
1
3 10 2.85 2.35 5.2
(
1.4 to 6.2
)
7
.10
(
1.61 to 9.63
)
1600
(
260 to 2170
)
1
31
3
2.60 2.60 5.2
(
1.4 to 6.2
)
7
.10
(
1.61 to 9.63
)
1600
(
260 to 2170
)
16
10
3
.
25
1
.
95
5
.
2
(
1.4 to 6.2
)
7
.
10
(
1.61 to 9.63
)
1600
(
260 to 2170
)
24
0
1 unit
10
–
2.7
–
2.7
(
1.1 to 3.2
)
2.78
(
1.31 to 3.51
)
6
00
(
220 to 800
)
1
3
–
3
.7
–
3.7
(
1.1 to 4.2
)
4.68
(
1.31 to 5.95
)
1100
(
220 to 1400
)
16
–
4
.
5
–
4
.
5
(
1.1 to 4.9)
6
.
38
(
1.31 to 7.23
)
1500
(
220 to 1700
)
2 un
i
t
s
10
1
0
2.
55
2.
55
5
.1
(
1.4 to 6.1
)
6
.
59
(
1.55 to 9.14
)
1
550
(
260 to 2150
)
1
3 10 2.85 2.35 5.2
(
1.4 to 6.2
)
6.80
(
1.55 to 9.23
)
1600
(
260 to 2170
)
13
13
2
.
60
2
.
60
5
.
2
(
1.4 to 6.2
)
6
.
80
(
1.55 to 9.23
)
1600
(
260 to 2170
)
16
1
0
3
.2
5
1
.
95
5
.2
(
1.4 to 6.2
)
6
.
80
(
1.55 to 9.23
)
1
600
(
260 to 2170
)
<
Heatin
g
>RAS-M18EAV-
E
Op
eration
m
o
de
V
o
l
t
s
Op
eration
S
tatu
s
Operatin
g
indoo
r
un
i
t
U
nit capacity (kW)
C
apacity
(
kW
)
R
unn
i
n
g
curren
t
P
ower Consum
p
tio
n
V
A
B
A
B
kW
A
W
Heating
220
1 un
i
t
10
-
4
.
0
-
4
.
0
(
0.7 to 5.2
)
5
.
57
(
1.10 to 7.88
)
1200
(
170 to 1700
)
13
-
5
.
0
-
5
.
0
(
0.7 to 6.5
)
8
.
35
(
1.10 to 11.73
)
1800
(
170 to 2530
)
16
-
5
.
5
-
5
.
5
(
0.7 to 6.9
)
8.81
(
1.10 to 11.73
)
1900
(
170 to 2530
)
2
u
nit
s
10
10
3
.
25
3
.
25
6
.
5
(
0.9 to 8.2
)
8
.
35
(
1.30 to 11.09
)
1800
(
200 to 2390
)
13
10
3
.
51
3
.
19
6
.7
(
0.9 to 8.5
)
8
.
58
(
1.30 to 11.36
)
1850
(
200 to 2450
)
1
31
3
3.35
3
.35 6.7
(
0.9 to 8.5
)
8.58
(
1.30 to 11.36
)
1850
(
200 to 2450
)
16
10
3
.
88
2
.
82
6
.7
(
0.9 to 8.5
)
8
.
58
(1.30 to 11.36
)
1850
(
200 to 2450
)
2
30
1 unit
10
-
4
.
0
-
4.
0
(
0.7 to 5.2
)
5
.
3
2
(
1.06 to 7.54
)
12
00
(
170 to 1700
)
1
3
-
5.0
-
5.0
(
0.7 to 6.5
)
7.99
(
1.06 to 11.22
)
1800
(
170 to 2530
)
16
-
5
.
5
-
5
.
5
(
0.7 to 6.9
)
8
.
43
(1.06 to 11.22
)
1900
(
170 to 2530)
2 un
i
t
s
10
1
0
3
.2
5
3
.2
5
6
.
5
(
0.9 to 8.2
)
7.
99
(
1.24 to 10.60
)
1
800
(
200 to 2390
)
1
3 10 3.5
1
3
.19 6.7
(
0.9 to 8.5
)
8.21
(
1.24 to 10.87
)
1850
(
200 to 2450
)
13
13
3
.
35
3
.
35
6
.7
(
0.9 to 8.5
)
8
.
21
(1.24 to 10.87
)
1850
(
200 to 2450
)
16
10 3.8
8
2.82 6.7
(
0.9 to 8.5
)
8.21
(
1.24 to 10.87
)
1850
(
200 to 2450
)
240
1
u
nit
10
-
4
.0
-
4.0
(
0.7 to 5.2
)
5
.10
(
1.01 to 7.23
)
1200
(
170 to 1700
)
13
-
5
.
0
-
5
.
0
(
0.7 to 6.5
)
7.
65
(1.01 to 10.76
)
1800
(
170 to 2530
)
16
-
5.5
-
5.5
(
0.7 to 6.9
)
8.08
(
1.01 to 10.76
)
1900
(
170 to 2530
)
2 unit
s
10
10 3.25
3
.25 6.5
(
0.9 to 8.2
)
7.65
(
1.19 to 10.16
)
1800
(
200 to 2390
)
13
10
3
.
51
3
.
19
6
.7
(
0.9 to 8.5
)
7.
8
7 (1.19 to 10.42
)
1850
(
200 to 2450
)
1
31
3
3.35
3
.35 6.7
(
0.9 to 8.5
)
7.87
(
1.19 to 10.42
)
1850
(
200 to 2450
)
16
10 3.8
8
2.82 6.7
(
0.9 to 8.5
)
7.87
(
1.19 to 10.42
)
1850
(
200 to 2450
)
The above specification values are those under the conditions
Cooling Indoor: DB/WB=27/19°C
Outdoor: DB=35°C
Heating Indoor: DB=20°C
Outdoor: DB/WB=7/6°C