– 52 –
Item
15. Clean
operation
Operation flow and applicable data, etc.
Description
1. Purpose
The clean operation is to minimize
the growth of mold, bacteria etc. by
running the fan and drying so as to
keep the inside of the air condi-
tioner clean.
Clean operation
When the cooling or dry operation
shuts down, the unit automatically
starts the clean operation which is
then performed for the specified
period based on duration of the
operation which was performed
prior to the shutdown, after which
the clean operation stops. (The
clean operation is not performed
after a heating operation.)
2. Operation
1) When the stop signal from the
remote controller is received, the
S.CLEAN indicator (green) on the
main body lights, and the clean
operation starts. (Neither the
OPERATION indicator nor the
TIMER indicator light.)
2) The period of the clean operation is
determined by the duration of the
operation performed prior to the
reception of the stop code.
3) After the clean operation has been
performed for the specified period,
the unit stops operating.
• During clean operations: The louver opens slightly.
The indoor fan operates continuously at a speed of
260 rpm.
Clean operation times
• To stop an ongoing clean operation at any time
Press the start/stop button on the remote controller
twice during the clean operation. (After pressing the
button for the first time, press it for the second time
without delay (within 10 minutes).)
Unit now performing cooling or
dry operation
Push "stop" button
Only S.CLEAN indicator lights,
and clean operation starts
Time set now elapses
Operation stops
Operation mode Operation time
Cooling:
Auto (cooling)
Dry
Heating:
Auto (heating)
Auto (fan only)
Shutdown
Up to 10 minutes
From 10 minutes
up to 1 hour
1 hour or longer
No clean operation performed
Clean operation time
No clean operation
performed (0 minutes)
2 hours
4 hours