Toshiba CONCEALED DUCK TYPE Air Conditioner User Manual


 
– 19 –
2-3. Ceiling Type
RAV-SM564CT
, RAV-SM804CT
, RAV-SM1104CT
, RAV-SM1404CT
Upper pipe draw-out port (Knockout hole)
Power supply cable take-in port (Knockout)
Remote controller cable take- in port
(Knockout hole)
Left drain size
B (Hanging position)
A
Refrigerant pipe
(Liquid side ØC)
Refrigerant pipe (Gas side ØD)
Drain pipe connecting port
Drain port VP20
(Inner dia. Ø26, hose attached)
Pipe draw-out port (Knockout hole)
200 (Liquid pipe)
216 (Gas pipe)
Power supply cable take-in port (Knockout hole)
Remote controller cable take- in port
Remote controller cable take- in port
(Knockout hole)
Outside air take-in port
(Duct sold separately)(Knockout hole Ø92)
Pipe hole on wall (Ø100 hole)
Drain left pipe draw-out port (Knockout hole)
Wireless sensor
mounting section
SM56 type
SM80 type
SM110, 140 type
Model name A B C D
910
1180
1595
855
1125
1540
Ø6.4 Ø12.7
Ø9.5 Ø15.9
(Hanging position)
84
135 84
262
347
171
145
32
32
90
92
53
70
130
680
41
114
50
170320
128
110
146
75 97
76
216 167
105
210
Hanging bolt
Ceiling surface
Unit
Within
50
250 or more250 or more
500 or more