Regency P40-LP Indoor Fireplace User Manual


 
Regency
®
P40 Direct Vent Gas Fireplace 41
MAINTENANCE
1) Unplug the power source.
2) Remove the Power Module by lifting it up
off of the velcro and pull out.
Power Module
3) Remove the Power Module cover by
removing the 2 screws, one on each side
of the box.
4) Unplug all wires connected to the Power
Module (J1, J2 & J3 on the power module
circuit board).
5) Pull Power Module off of pins and replace.
6) Reverse steps to re-install.
Power Module
3) Remove the Control Module by lifting it up
off of the velcro and pull out.
1) Unplug the power source.
2) Remove the Power Module by lifting it up
off of the velcro and pull out.
Control Module
4) Remove the Heat Shield from the Control
Module by removing the 2 screws.
Heat Shield
5) Unplug all wire harnesses and manual
control box cable plugged into the Control
module.
6) Replace the Control Module and reverse
steps to re-install.
POWER MODULE
REPLACEMENT
CONTROL MODULE
REPLACEMENT
MAINTENANCE
J1
J2
J3
1) Unplug the power source.
2) Remove the Power Module by lifting it up
off of the velcro and pull out.
Power Module
3) Remove the Power Module cover by
removing the 2 screws, one on each side
of the box.
4) Replace the 9V and AA battery and reverse
steps to re-install.
BACKUP BATTERY
REPLACEMENT
(within Power Module)
NOTE: The 9V battery operates the rear
burner and the AA battery operates
the DC Sparker for lighting the pilot
under power outage conditions.